
3. Advanced Commands
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Answer)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\xa7
Data [0]
\x00
Checksum
\xc9
Stop
\xff
3.31.14 Minimum VCO, Read
Description
Reads the minimum (range) VCO value of the projector
Command
Command [0]
\x26
Command [1]
\xa8
Returned Data
Data [0] = minimum VCO value
3.31.15 Maximum VCO, Read
Description
Reads the Maximum (range) VCO value of the projector
Command
Command [0]
\x27
Command [1]
\xa8
Returned Data
Data [0] = Maximum VCO value
3.31.16 Charge pump current, Increment/Decrement
Description
Increments/decrements the charge pump current by one
Commands
increment:
R5976884 RLM SERIES 04/04/2006
151