6. General Menu
Image 6-11
6.7 Reset runtime
When to reset the lamp runtime ?
The lamp runtime should only be reset when placing a new lamp.
How to reset the lamp runtime ?
1. Press
MENU
to activate the Toolbar
2. Press
→
to select the
General
item
3. Press
↓
to Pull down the
General
menu
4. Use
↑
or
↓
to select
Reset runtime
5. Press
→
to pull down the menu
6. Use
↑
or
↓
to select the lamp to be reset (image 6-12)
7. Press
ENTER
A dialogbox is displayed (image 6-13)
8. Use
←
or
→
, the numeric keys on the remote, or the keypad to change the serial number of the lamp (serial number 0000000 will
not be accepted).
Image 6-12
R5976495 BARCOREALITY SIM 6 ULTRA MM 22102002
39