12. Image Files Menu
12.6.2 Correct file parameters
What is already available during start up ?
During the installation of a file with LOAD, the horizontal period, the total number of vertical lines and the interlaced mode are
automatically measured and filled in. These values will be available when starting up the EDIT procedure of an active file.
Adjustable items
•
Active horizontal pixels : determine the width of the window on the screen. This value is normally given in the source specifi-
cations. If not, adjust until full image is displayed (no missing pixels).
•
Horizontal start in pixels : number of pixels between the beginning of the input signal and the start of the video information in
the signal.
•
Horizontal period in ns : when active file, the correct value will be filled out.
•
Active vertical lines : number of horizontal lines determining the height of the projected image. this value is normally given in
the specification of the source. If not, adjust until full image height is displayed (no missing lines).
•
Vertical start in lines : number of lines between the start of the input signal and start of the image on the screen.
12.6.3 Advanced video settings
Overview
When a video source is selected, the
advanced
button enables the advanced settings for that video source.
Advanced edit
Comb filter
On
Off
AGC hold interval
Short
Long
Sync locking
Slow
Fast
Sharpness
Coarse
Fine
Image 12-9
video signal
video signal
frame blanking
HI
egalisation
Image 12-10
HI AGC Hold interval
The
Comb filter
is by default enabled.
The
AGC hold interval
is the time interval in which the AGC is inhibited (AGC hold = no update in video amplitude measurement),
the advanced parameter allows to choose a short or long hold interval.
A long AGC hold interval eliminates Macrovision
®
disturbances since the AGC is hold during a long interval, thus reducing the
probability to encounter a Macrovision
®
pulse.
The
sync locking setting
is recommended for poor video signals (ex: poor TV signals).
Sharpness
adjustment can be chosen to be coarse or fine.
It is recommended to use the default values.
12.6.4 Advanced Data settings
Overview
When a data source is selected, the
advanced
button enables the advanced settings for a data source.
112
R5976817 RLM H5 17/01/2005
Summary of Contents for R9010300
Page 1: ...RLM H5 Owners manual R9010300 R5976817 00 17 01 2005...
Page 4: ......
Page 8: ...Table of contents 4 R5976817 RLM H5 17 01 2005...
Page 14: ...1 Packaging and Dimensions 10 R5976817 RLM H5 17 01 2005...
Page 54: ...5 Getting used with the menu structure 50 R5976817 RLM H5 17 01 2005...
Page 60: ...6 Source selection 56 R5976817 RLM H5 17 01 2005...
Page 64: ...7 General Menu Image 7 7 60 R5976817 RLM H5 17 01 2005...
Page 91: ...8 Image Menu Image 8 46 R5976817 RLM H5 17 01 2005 87...
Page 92: ...8 Image Menu 88 R5976817 RLM H5 17 01 2005...
Page 102: ...9 Tools Menu 98 R5976817 RLM H5 17 01 2005...
Page 122: ...12 Image Files Menu 118 R5976817 RLM H5 17 01 2005...
Page 136: ...13 Display Setup 132 R5976817 RLM H5 17 01 2005...
Page 146: ...14 Installation menu 142 R5976817 RLM H5 17 01 2005...
Page 158: ...A Standard Image Files 154 R5976817 RLM H5 17 01 2005...