![Barco R9002384 Owner'S Manual Download Page 54](http://html1.mh-extra.com/html/barco/r9002384/r9002384_owners-manual_4231258054.webp)
Downloaded from Projector.com
7-11
5976197 BARCOCINE 7 10012001
Random Access Adjustment Mode
menu 1
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
LINE MULTIPLIER
TIME BASE CORRECTION
LUMINANCE DELAY
V SYNC REF :
INDIRECT
CLAMP GATING : OFF
LIMO PLUS OPTIONS
FACTORY PRESET
WARNING : ADVANCED
ADJUSTMENT SHOULD BE
PERFORMED ONLY BY QUALIFIED
PERSONNEL
menu 1
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
LINE MULTIPLIER
TIME BASE CORRECTION
LUMINANCE DELAY
V SYNC REF : INDIRECT
CLAMP GATING :
OFF
LIMO PLUS OPTIONS
FACTORY PRESET
WARNING : ADVANCED
ADJUSTMENT SHOULD BE
PERFORMED ONLY BY QUALIFIED
PERSONNEL
Vertical Sync Reference
Why necessary ?
e.g. When spooling a tape and start playing the image, it is possible that the image still rolls for ± 2 frames. This can be avoid by changing
the vertical sync reference to direct.
How to change the vertical sync reference ?
1. Push the cursor key
é
or
ê
to select 'V Sync Ref' (menu 1).
2. Press
ENTER
to toggle between 'direct' and ' indirect'.
Default position : indirect.
Clamp Gating
Why necessary ?
When Time Base Correction is ON, Clamp gating should be set to ON (caution : Set H sync ref. to indirect).
Also e.g. with bad video tapes or with video signals with negative pulses in the information part of the signal.
How to change the Clamp Gating ?
1. Push the cursor key
é
or
ê
to select 'Clamp Gating' (menu 1).
2. Press ENTER to toggle between ON and OFF.
Default position : OFF.