3. Components of the Green BCM Solution
CONTROL IN, CONTROL OUT
The CONTROL OUT interface of the Green BCM Box is connected to the CONTROL IN interface of the first Power
Module 19inch.
The CONTROL OUT interface of the first Power Module 19inch. is connected to the CONTROL IN interface of the
following Power Module 19inch.
Always connect the CONTROL OUT interface of the previous Power Module 19inch. to the CONTROL IN interface of
the following Power Module 19inch.
A shortening plug needs to be plugged into CONTROL OUT interface of the last Power Module 19inch.
The green power switch is always looking
for a zero crossing on the phase of the
power net. If no power net is connected, the
Green Power Switch will not switch to on
mode.
L'interrupteur d'alimentation vert est
toujours à la recherche d'un passage à zéro
sur la phase du filet de puissance. Si aucun
filet d'alimentation est branché, le Green
Power Switch ne se allume pas.
3.3
Complete solution
The Green Power Switches (2) will be installed on a DIN RAIL next to Green BCM Box (1).
This solution is completed by the Green ONOFF button to switch the display wall from standby into operation and
vice versa and also mounted to the DIN RAIL.
The max. distance between Green ONOFF button the Green BCM BOX is 5m.
Barco – Green BCM Solution – R591346 – user's manual – Revision 04– November-2016
____________________________________________________________________
22