Video input signals
4K-UHD input
•
1x DP 1.1 up to 3840 x 2160 @30Hz
•
2x DP 1.1 up to 1920 x 2160 @50Hz/60Hz
•
1x DP 1.2 MST up to 3840 x 2160 @50Hz/60Hz
2x FO SFP+ for 4K-UHD Nexxis link
FHD input (upscaled to UHD)
•
1x DVI
•
1x 3G-SDI
Video output signals
1x 3G-SDI (3G-SDI input loopthrough)
1x DVI (image on screen downscaled to FHD)
Video formats
•
Display Port 1.2 MST (10 bit) up to 3840x2160 @60Hz RGB 30bits/pixel
•
Dual stream DP 1.1 (10-bit) up to 1920x2160 x2 @60Hz RGB 30bits/
pixel
•
HDMI 2.0 up to 3840x2160 @60Hz RGB/YCbCr (4:2:0/4:2:2/4:4:4) with
HDCP 2.2 and 1.4
•
HDMI 1.4 up to 3840x2160 @30Hz RGB/YCbCr (4:2:2/4:4:4) with HDCP
1.4
Integrated Nexxis 4k decoder
MNA-240 decoder integrated
Remote control
FW download, DDC protocol on DVI and DP auxiliary channel (on DP main
connector) & control protocol through network connection
Power consumption (Max)
170 W ± 10%
Power requirements
100-240 VAC / 50-60 Hz / 1.8-0.9 A
DC power output
DVI connector: +5V on pin 14 & 16 / 500mA
DP connector: +3.3V / 500mA
USB connector: +5V / 1A
DC out connector: +5V / 2A
Power management
Low power mode: 52 W (typical)
Power-off: ~ 1 W
Dimensions display (W x H x D) 1265 x 770 x 85 mm (49.8 x 30.3 x 3.3 in)
Net weight display
With front protection glass: 33.6 kg (74.1 lbs)
Without front protection glass : 24.6 kg (54.2 lbs)
Net weight packaged
With front protection glass: 40.1 kg (88.4 lbs)
Without front protection glass : 31.1 kg (68.6 lbs)
Mounting standard
VESA (200 mm, 600 mm)
Certifications
•
ANSI/AAMI ES 60601-1:2005/(R)2012 and A1:2012, C1:2009/(R)2012
and A2:2010/(R)2012 - Med. El. Equip., Part 1: general req. for basic
safety and essential performance
•
CAN/CSA-C22.2 No. 60601-1: 14 Medical Electrical Equipment - Part 1:
General Requirements for Basic Safety and Essential Performance
(Harmonized with Ed. 3.1)
•
IEC 60601-1: 2012 Edition 3.1 (Medical electrical equipment
–
Part 1:
General requirements for basic safety and essential performance)
•
EN 60601-1: 2006 + A1:2013 (Medical electrical equipment - Part 1:
General requirements for safety)
•
Electromagnetic Compatibility: EMC Medical EMC Standards:
IEC60601-1-2 (4th Ed), EN55011 /CISPR 11, FCC CFR47 part 15 & 18/
Class B
•
Approvals/Marking: CE (Medical Device Class I), c-UL-us, DEMKO,
KCC, CCC, INMETRO
•
RoHS-3, REACH, WEEE
Operating temperature
0 ÷ 35 °C (for performance); 0 ÷ 40 °C (for safety)
Storage temperature
-20 ÷ +60°C
Operating humidity
10 ÷ 90% (non-condensing)
Storage humidity
5 ÷ 90% (non-condensing)
Summary of Contents for K9352021
Page 5: ...5 K5902133 451920612484 03 MDSC 8255 Welcome 1...
Page 8: ...K5902133 451920612484 03 MDSC 8255 8 Welcome...
Page 9: ...9 K5902133 451920612484 03 MDSC 8255 Parts controls and connectors 2...
Page 15: ...15 K5902133 451920612484 03 MDSC 8255 Display installation 3...
Page 21: ...21 K5902133 451920612484 03 MDSC 8255 Daily operation 4...
Page 26: ...K5902133 451920612484 03 MDSC 8255 26 Daily operation...
Page 40: ...K5902133 451920612484 03 MDSC 8255 40 Advanced operation...
Page 41: ...41 K5902133 451920612484 03 MDSC 8255 Important information 6...