2. System Overview

The power cords delivered with the ILite display system have special properties for safety. They are not user
serviceable. If the power cords are damaged, replace only with new ones. Never try to repair a power cord.

Order info:

Article No.

Description

Image

R9851130

One ILite power linking cable (C20 / C19 / C13).

Used to distribute power between tiles. Maximum 6 tiles per branch.

image 2-8

R9851131

Package with 5 ILite power linking cables (C20 / C19 / C13).

Used to distribute power between tiles. Maximum 6 tiles per branch.

image 2-8

R9851132

Package with 10 ILite power linking cables (C20 / C19 / C13).

Used to distribute power between tiles. Maximum 6 tiles per branch.

image 2-8

R9851140

ILite power source cable (C20 waterproof / C19) 4,5 meter.

Used to distribute power from the

Fiberlink Receiver

to an

ILite tile

.

image 2-9

R9851150

ILite power source cable (C20 waterproof / C19) 9 meter.

Used to distribute power from the

Fiberlink Receiver

to an

ILite tile

.

image 2-10

R9851136

ILite power source cable (C20 / C19 waterproof) 2,5 meter.

Used to distribute power from an

ILite tile

to the

Fiberlink Receiver

.

image 2-11

R9851141

ILite power source cable (C20 / C19 waterproof) 4,5 meter.

Used to distribute power from an

ILite tile

to the

Fiberlink Receiver

.

image 2-12

R9851151

ILite power source cable (C20 / C19 waterproof) 9 meter.

Used to distribute power from an

ILite tile

to the

Fiberlink Receiver

.

image 2-13

R9851160

ILite power source cable (CEE / C19) 2,5 meter.

Use to distribute power directly from the wall outlet to maximum 6 ILite tiles.

image 2-14

R9851170

ILite power source cable (CEE / C19) 4 meter.

Used to distribute power directly from the wall outlet to maximum 6 ILite tiles.

image 2-15

R9851180

ILite power extension lead (C20 / C19) 1,5 meter.

image 2-16

R9851190

ILite power extension lead (C20 / C19) 2,5 meter.

image 2-17

R9851200

ILite power extension lead (C20 / C19) 4 meter.

image 2-18

R9851260

Multi power cable of 10 meter.

Used to distribute power between

Custom Power Box

and

Spider

connector.

R9851261

Multi power cable of 20 meter.

Used to distribute power between

Custom Power Box

and

Spider

connector.

R9851262

Multi power cable of 30 meter.

Used to distribute power between

Custom Power Box

and

Spider

connector.

R9851263

Multi power cable of 50 meter.

Used to distribute power between

Custom Power Box

and

Spider

connector.

R9851264

Multi power cable with custom length.

Used to distribute power between

Custom Power Box

and

Spider

connector.

image 2-19

R9851670

ILite Spider connector with 6 power outputs (C19) with different lengths. Spider support
bracket included.

Used to distribute power from a

multi power cable

to the

ILite tiles

. Maximum six

ILite tiles per Spider output cable.

R5976522 FIXED ILITE DISPLAY 05042004

15

Summary of Contents for ILite Series

Page 1: ...MEDIA FIXED ILITE DISPLAY INSTALLATION MANUAL For I6 I6 XP I8 I10 I12 tiles 05042004 R5976522 02 ...

Page 2: ...Barco nv Media Noordlaan 5 B 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail media barco com Visit us at the web www barco com Printed in Belgium ...

Page 3: ...e claims of the purchaser will be rendered invalid Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either The environmental conditions as well as the servicing and maintenance regulations sp...

Page 4: ......

Page 5: ...er boxes 18 2 7 Digitizer 18 2 8 Fiberlink system 18 2 9 Control software 18 3 Physical installation 19 3 1 Installation of the support structure 19 3 2 Preparation of the ILite assembly blocks 19 3 2 1 Assembly block positioning code 19 3 2 2 Removing sides from ILite assembly blocks 20 3 2 2 1 Removing sides 20 3 2 2 2 Removing the left side from an ILite assembly block 21 3 2 2 3 Removing the b...

Page 6: ...Table of contents 2 R5976522 FIXED ILITE DISPLAY 05042004 ...

Page 7: ...turing processes in order to achieve part strength Consult Barco for assistance with custom applications Always follow Barco installation instructions Contact Barco if you should have any question regarding the safety of an application The manufacturer assumes no liability for incorrect inadequate irresponsible or unsafe assembly of systems Product care Structural mounting components should be kep...

Page 8: ...arts must be undertaken immediately Protect the power data cords from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Replace damaged power data cords immediately Only use attachments accessories specified by the manufacturer Disconnect the power to this apparatus during lightning storms or provide suitable additional lightn...

Page 9: ... switched off Risk of electric shock Risk of fire To protect against risk of fire by overloading of power cables MAXIMUM 6 TILES in one column may be connected in parallel Each source cable supplying a column of MAXIMUM 6 TILES should be protected by a circuit breaker or fuses rated 16 A 250 V Disconnect device When the appliance inlets of the individual tiles are not accessible the socket outlets...

Page 10: ...1 Safety 6 R5976522 FIXED ILITE DISPLAY 05042004 ...

Page 11: ...er boxes Digitizer Fiberlink system Control software 2 1 Introduction The fundamental elements of a ILite display system are Support structure Assembly blocks ILite display tiles Power box Digitizer Control software Block diagram ILite display system Sources Digitizer Control PC RS232 Tile 1 Tile 2 Tile 3 ILite Display Image 2 1 R5976522 FIXED ILITE DISPLAY 05042004 7 ...

Page 12: ... H7 x V5 ILite display The support structure in the above example is pure illustrative for a H7 x V5 ILite display Several variants of support structures are possible for the same size of an ILite display Contact Barco NV for more information 2 3 Assembly blocks for an ILite display system 2 3 1 ILite assembly blocks Introduction The assembly of a system due to the multitude of possible screen siz...

Page 13: ...ut its inherent technology limits as hotspot effect jailhouse effect alignment problems and low contrast level But offering shallow depth long lifetime increased ruggedness and incredible picture dynamics Built in intelligence provides for auto calibration of the full display hot swap of tiles and diagnostic capabilities An embedded PC equips every ILite tile providing it with intelligence and adv...

Page 14: ... 12 tile 2 4 3 Technical summary ILite tiles 2 4 3 1 Specifications ILite 6 tile Specifications Contrast Ratio 950 1 500 lux 1 625 1 225 lux Screen size Unlimited Weight 13 kg Hor viewing angle 145 Vert viewing angle 145 Avg Power Consumption 100 W tile Max Power Consumption 400 W tile Tile dimensions Width 0 448 m Height 0 448 m Depth 0 1495 m Visual Resolution 6 mm 10 R5976522 FIXED ILITE DISPLA...

Page 15: ...6500 K LED configuration 3 in 1 SMD Pixel density 25 920 m 2410 ft 5 184 tile 72x72 Hor viewing angle 145 min 50 brightness Vert viewing angle 145 min 50 brightness Contrast Ratio 950 1 Lifetime 45000h full white half brightness Power consumption maximum 400W tile average 100W tile Colors 4 4 trillion Weight 13 Kg 28 7 lbs Processing 14bit color Color 8bit color Greyscale Refresh rate 400 Hz PAL N...

Page 16: ...le Tile dimensions Width 0 448 m Height 0 448 m Depth 0 1495 m Visual Resolution 8 mm Brightness 2 500 NIT Calibrated Brightness 2 000 NIT Temperature range operating 0 C 40 C storage 20 C 60 C Lifetime 45 000h half brightness Processing 10 bit Source compatibility S Video Composite YUV RGB SDI HDSDI Data DVI up to UXGA 2 4 3 4 Specifications ILite 10 tile Specifications Contrast Ratio 950 1 500 l...

Page 17: ...tile Specifications Brightness 2 500 NIT Calibrated Brightness 2 000 NIT Contrast Ratio 950 1 500 lux 1 625 1 225 lux Visual Resolution 12 mm Hor viewing angle 145 Vert viewing angle 145 Tile dimensions Width 0 448 m Height 0 448 m Depth 0 1495 m Weight 13 kg Avg Power Consumption 100 W tile Max Power Consumption 400 W tile Temperature range operating 0 C 40 C storage 20 C 60 C Screen size Unlimit...

Page 18: ... configuration of the ILite display several sizes and types of power cables are needed The picture below image 2 6 illustrates the available power connector types for an ILite Display Image 2 6 Power connector types A Type CEE male B Type C13 female C Type C19 female D Type C20 male Image 2 7 Detail male multi pole connector Used on the Custom Power Box multi power cable and Spider connector 14 R5...

Page 19: ...851151 ILite power source cable C20 C19 waterproof 9 meter Used to distribute power from an ILite tile to the Fiberlink Receiver image 2 13 R9851160 ILite power source cable CEE C19 2 5 meter Use to distribute power directly from the wall outlet to maximum 6 ILite tiles image 2 14 R9851170 ILite power source cable CEE C19 4 meter Used to distribute power directly from the wall outlet to maximum 6 ...

Page 20: ... tiles Maximum six ILite tiles per Spider output cable R9851672 ILite Spider connector with 6 power outputs C19 with custom lengths Spider support bracket included Used to distribute power from a multi power cable to the ILite tiles Maximum six ILite tiles per Spider output cable Image 2 8 Image 2 9 Image 2 10 Image 2 11 Image 2 12 Image 2 13 Image 2 14 Image 2 15 Image 2 16 16 R5976522 FIXED ILIT...

Page 21: ...ype plugs Used to link data from ILite tile to ILite tile R9851680 Package with 10 white DVI DVI data cables of 0 9 meter screw type plugs Used to link data from ILite tile to ILite tile image 2 21 R9851210 DVI DVI data cable of 5 meter screw type plugs Used to link data from D320 Digitizer to ILite tile image 2 22 R9851217 MDR waterproof DVI data cable of 5 meter Used to link data from Fiberlink ...

Page 22: ...onnected to the digitizer through a serial RS232 connection Refer to the manual of the digitizer for more information about the digitizer 2 8 Fiberlink system General The data signal coming out of the digitizer is transported from the digitizer to the display by a high speed data link To send such a high density stream of data over long distances a fiber optic cable is required Barco offers a comp...

Page 23: ...ter the assembly blocks and tiles are attached raised as one structure to its vertical position and installed 3 2 Preparation of the ILite assembly blocks 3 2 1 Assembly block positioning code Understanding the position code Each assembly block is coded with a letter followed by two numbers The letter indicates the ILite display to which this assembly block is part of very useful incase there is m...

Page 24: ...tom side or both left side bottom but never top or right because the ILite display wall is always build from left to right and bottom to top No sides need to be detached from de first assembly block coded x 1 1 which is located in the lower left corner of the ILite display From the assembly blocks located in the first row bottom row of the ILite display only the left side need to be detached From ...

Page 25: ... on the left side of the assembly block about three centimeters to the right by loosen the hexagon bolts image 3 6 Image 3 4 A Carrier strap to remove Image 3 5 Left side removed Image 3 6 Three centimeters shift of the aluminium corner brackets The 3 cm shift is necessary because otherwise it is impossible to place the assembly block against both other joining assemblies After placement of this a...

Page 26: ...int consists of two aluminium profiles one aluminium corner two hexagon bolts and two nuts Necessary tools Allen key 4 mm Making a basic connection joint 1 Ensure both nuts are in the correct position 90 degrees turned compared to the aluminium profiles image 3 8 2 Ensure no gap between the two profiles image 3 9 3 Check if the sides of both profiles are in the same plane image 3 9 4 Ensure the an...

Page 27: ... attached to the support structure in succession and interconnected with one another Starting in the lower left corner of the ILite display with the first assembly block coded x 1 1 from left to right and from bottom row to top row For connections of the assembly blocks ensure only the recommended variants are used to comply with safety guidelines It s important that every assembly block is assemb...

Page 28: ...for an ILite display H7xV5 ILite fixation clamp Per attachment point an ILite fixation clamp is required article no for 2 pieces R9851450 A B C D E Image 3 11 ILite fixation clamp A Mounting plate B 2 mm shim plate C 1 mm shim plate D 0 5 mm shim plate E Support bracket 24 R5976522 FIXED ILITE DISPLAY 05042004 ...

Page 29: ...ssembly block see Preparation of the ILite assembly blocks page 19 4 Place the prepared assembly block into position on the support structure with the top of the assembly block up 5 Fasten the assembly block with aluminium corners and hammer bolts to the other adjoining assembly block s see Correct alignment of the ILite assembly blocks page 22 image 3 14 image 3 15 Note For assembly reasons is it...

Page 30: ...Mounting assembly block A 1 2 into a ILite H7 x V5 display A Vertical adjoining edge Vertical adjoining edge A Horizontal adjoining edge B Image 3 15 Example 2 Mounting assembly block A 2 2 into a ILite H7 x V5 display A Vertical adjoining edge B Horizontal adjoining edge 3 5 ILite tile mounting What has to be done ILite tile units are to be fixed into the wall assembly 26 R5976522 FIXED ILITE DIS...

Page 31: ...g bolts If not insert those bolts first image 3 17 2 Ensure the tile is in the right position so top up 3 Place the ILite tile into the wall assembly by guiding the positioning bolts through the corresponding positioning holes of the wall assembly image 3 18 4 Secure the ILite tile with 4 ILite tile lock nuts from the rear of the wall assembly A A B B A A Image 3 17 A Location on ILite tile for po...

Page 32: ...ports The data ports consist in two DVI connectors situated on the resync unit The resync unit auto detect the incoming signal on one of the two DVI connectors The other DVI connector will automatically act as data output port So it doesn t matter on which DVI connector the data is coming in the ILite tile switch the functionality of the DVI connectors spontaneously between input and output The IL...

Page 33: ...t tile in a column of maximum six image 3 20 3 Complete each power branch by connecting maximum six tiles with power linking cables to each other in a daisy chain manner The female C13 plug of the power linking cable is plugged directly in the tile The male C20 and the female C19 plugs serve as power loop through The last female C19 plug in the chain is unused Warning Maximum 6 six tiles per power...

Page 34: ...e Mono Phase Power Box B Ouput cable C Power Linking Cable D FIrst ILite tile in a column of maximum six A power branch consisting in a column of maximum six tiles may be interrupted to provide a ILite display peripheral from power A maximum of one ILite display peripheral is allowed per power branch of six tiles 30 R5976522 FIXED ILITE DISPLAY 05042004 ...

Page 35: ...ut cable D Power linking cable 3 6 2 2 Connections with a Custom Power Box Necessary parts Custom Power Box Multi power cables ILite Spider connector with Spider support bracket Power linking cables Cable ties Power connections 1 Install the Custom Power Box on a safe location near by the ILite display 2 Connect a multi power cable with an adapted length with one of the multi pole connectors on th...

Page 36: ... MULTI POWER CABLE Multi pole B ILite Spider Connector C POWER DATA ILite Tile D POWER LINKING CABLE E POWER DATA POWER DATA Image 3 22 A Custom Power Box B Multi power cable Multi pole C ILite Spider connector D First ILite tile in a column of maximum six E Power linking cable Image 3 23 Spider support bracket 3 6 3 Data cabling Necessary parts Data linking cables Data connections 1 Connect the d...

Page 37: ...s are daisy chained to all tiles B POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA PO...

Page 38: ...cally but for most installations the data source cabling is done in a horizon tally direction because the power cabling is done in vertical columns POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA POWER DATA...

Page 39: ... back of the tiles for loss of strength due to exposing to environmental conditions Replace damaged handles immediately before starting any servicing to the tiles Do not modify and or replicate any component BARCO uses specific materials and manufacturing processes in order to achieve part strength No other parts then BARCO parts are allowed 4 2 ILite tile diagnostic Status LED s resync unit The r...

Page 40: ...removing the lock nuts that the tile doesn t drop out at the front of the ILite display Hold with one hand the tile by one of the grip handles and remove with the other free hand the lock nuts 4 Grab the ILite tile with both hands by the grip handles and push the tile a little forwards out of the ILite display Hold tile securely 5 Lay the tile flat on both arms and rotate it diagonally 45º 6 Remov...

Page 41: ...e tile Do not remove the power linking cable out of the power branch 3 Remove the resync unit from the tile by releasing two screws on the resync unit 4 Replace the mall function tile by accessing it from the back with an other tile see Tile accessing page 36 5 Place the resync unit on the new tile and fasten with two screws 6 Insert the power cord into the new tile R5976522 FIXED ILITE DISPLAY 05...

Page 42: ...4 Servicing 38 R5976522 FIXED ILITE DISPLAY 05042004 ...

Page 43: ...ounting 26 O Order info 9 10 Assembly blocks 9 ILite tiles 10 Overview 18 Control software 18 Digitizer 18 Power boxes 18 P Positioning code 19 Power 29 31 Connections 29 31 Custom Power Box 31 Mono Phase Power Box 29 Power boxes 18 Preparation 19 Positioning code 19 R Removing sides 20 21 Bottom side 21 Left side 21 Which 20 Why 20 S Safety 3 5 35 Guidelines 3 Instructions 4 35 Warnings 5 Servici...

Reviews: