Network settings
What can be done?
These settings are used to set the Ethernet Communication parameters.
The Ethernet connection can be used to upload/download projector software and/or to set up communication (TCP-packets) with
the projector.
Following parameters are available :
MAC Address
MAC Address of the projector (This is a non-adjustable value programmed into the Ethernet
board).
IP Address (Current)
IP Address of the projector (This is a non-adjustable value ).
Subnet Mask
Subnet Mask (This is a non-adjustable value )
Gateway
Gateway (This is a non-adjustable value )
DHCP
DHCP setting:
•
Yes
: The projector will dynamically obtain its IP address from the DHCP server.
•
No
: The IP address needs to be entered manually. Note that when selecting
Fxed IP
the IP settings fields are enabled
IP Address
Fixed IP Address of the projector : this field can be edited when Fixed IP is selected
Subnet Mask
Subnet Mask : this field can be edited when Fixed IP is selected
Gateway
Gateway : this field can be edited when Fixed IP is selected
Hostname
Hostname : this field can be edited when DHCP is selected
How to set up the network settings ?
1. Press the
MENU
key to activate the Menu bar.
2. Push the cursor key
←
or
→
to highlight
Installation
in the menu bar.
3. Push the
↓
key to pull down the
Installation
menu.
4. Push the cursor key
↑
or
↓
to highlight
Network settings
and press
ENTER
to select.
Image 5-14
34
R59770079 BARCO ID H250/500 23/07/2007
Summary of Contents for iD H250
Page 1: ...Barco iD H250 500 Owners manual R9010520 R9010570 R59770079 01 23 07 2007...
Page 28: ...4 Connections 24 R59770079 BARCO ID H250 500 23 07 2007...
Page 41: ...5 Setup Image 5 18 7 Press ENTER R59770079 BARCO ID H250 500 23 07 2007 37...
Page 42: ...5 Setup 38 R59770079 BARCO ID H250 500 23 07 2007...
Page 44: ...6 Getting started 40 R59770079 BARCO ID H250 500 23 07 2007...
Page 88: ...7 Advanced Image 7 84 84 R59770079 BARCO ID H250 500 23 07 2007...
Page 96: ...7 Advanced 92 R59770079 BARCO ID H250 500 23 07 2007...
Page 98: ...8 Maintenance 94 R59770079 BARCO ID H250 500 23 07 2007...