![background image](http://html1.mh-extra.com/html/barco/icon-h250/icon-h250_owners-manual_3842195079.webp)
7. Advanced
B
Black level
0.7V
Image 7-36
Black level
∆
G
∆Β
∆
R
R
G
B
Image 7-37
The objective of input balancing
The objective in input balancing is to “set” the same black level and the same white level for the three colors of a particular input
source.
Black level setting : brightness
White level setting : contrast
The same absolute black and white level for the three colors allows the same reference for Brightness and contrast control of the
picture !
These two references also set the range in which the ADC will work for that particular source ( this explains also why each input
balance setting is linked to a particular source and thus saved in the image file).
How can it be done ?
To balance the three color signals of a particular source there are conditions; in fact we must know the black and the white level of
the source i.e. :
1.
the source in question must be able to generate a white signal, ideally a 100% white (background) full screen pattern
2.
the source in question must be able to generate a black signal, ideally a 100 % black (background) full screen pattern
A
B
Image 7-38
White balance : In the projector, we will set the contrast for each color until we get a 100% light output picture when projecting a
100% white image (image A)
Black balance : In the projector, we will set the brightness for each color until we get a 0% light output picture when projecting a
100% black image (image B).
The changeover from min to max is indicated by the apparition of bright spots also called “digital noise”
R5976992 ICON H250/400 13/12/2006
73
Summary of Contents for iCon H250
Page 1: ...iCon H250 400 Owners manual Preliminary R9010510 R9010500 R5976992 0A 13 12 2006...
Page 10: ...Table of contents 4 R5976992 ICON H250 400 13 12 2006...
Page 34: ...5 Connections 28 R5976992 ICON H250 400 13 12 2006...
Page 60: ...6 Setup 54 R5976992 ICON H250 400 13 12 2006...
Page 103: ...7 Advanced Image 7 84 R5976992 ICON H250 400 13 12 2006 97...
Page 130: ...8 Network centric operations 124 R5976992 ICON H250 400 13 12 2006...
Page 144: ...11 SNMP services 138 R5976992 ICON H250 400 13 12 2006...
Page 146: ...12 Maintenance 140 R5976992 ICON H250 400 13 12 2006...
Page 152: ...13 Image files 146 R5976992 ICON H250 400 13 12 2006...