7. GUI – Image
Image 7-7
Advanced menu — P7 Realcolor
The P7 menu is displayed.
Image 7-8
P7 Realcolor menu
2. Select the desired
Mode
. Choose one of the following:
-
Native
: Default mode, with default values. All other options in the P7 menu are disabled.
-
Custom RGB
: 3–point color con
fi
guration. In RGB mode, the C, M and Y coordinates will be calculated automatically based
on the R, G and B coordinates.
-
Custom RGBCMY
: 6–point color con
fi
guration (both RGB and CMY). In RGBCMY mode, each color can be given a speci
fi
c
coordinate within the measured color triangle.
-
Custom WHITE
: Con
fi
gure only the White temperature.
3. De
fi
ne the coordinates for each available color.
Click on a coordinate value and select the current value. Enter the desired value with the numeric keys.
Note:
You can only pick coordinates within the measured color triangle.
4. For
Custom White
, click on White point and choose one of the following:
-
Coordinates
: Con
fi
gure the white point via speci
fi
c coordinates. The white point is speci
fi
ed using an x, y coordinate in the
CIE 1931 Chart.
-
Temperature
: Con
fi
gure the white point via a color temperature slider. The white point is speci
fi
ed on a Kelvin scale between
3200K and 13000K tracking along the black body curve.
You can reset all coordinates to the default values (to native) by selecting Reset modes to native. Press OK
button to reset.
7.3
HDR – Perceptual Quantizer (PQ)
About PQ
Perceptual Quantizer (PQ) is a, electro-optical transfer function (EOTF) that allows for the display of High Dynamic Range (HDR)
content with a luminance level of up to 10 000 cd/m² and can be used with the Rec. 2020 color space.
If your provided HDR content has been mastered with Perceptual Quantzier (e.g. Dolby Vision or HDR10), you can adapt the
luminance on screen to adapt to the provided content.
For optimal display of HDR content, this is just one value that will in
fl
uence the projected image. When enter-
ing the desired screen luminance, take into account the distance of the projector to the screen and the quality
of the screen used.
How to set the PQ?
1. In the main menu, select
Image
→
Advanced
→
PQ
.
R5906852 F80 SERIES 21/09/2017
41
Summary of Contents for F80-4K7
Page 1: ...F80 series User Manual R5906852 00 21 09 2017...
Page 4: ......
Page 16: ...1 Safety 12 R5906852 F80 SERIES 21 09 2017...
Page 19: ...2 Remote Control Unit 1 Image 2 5 R5906852 F80 SERIES 21 09 2017 15...
Page 20: ...2 Remote Control Unit 16 R5906852 F80 SERIES 21 09 2017...
Page 26: ...3 Input Communication 22 R5906852 F80 SERIES 21 09 2017...
Page 36: ...4 Getting Started 32 R5906852 F80 SERIES 21 09 2017...
Page 40: ...5 Graphic User Interface GUI 36 R5906852 F80 SERIES 21 09 2017...
Page 74: ...9 GUI System Settings 70 R5906852 F80 SERIES 21 09 2017...
Page 76: ...10 Status menu 72 R5906852 F80 SERIES 21 09 2017...
Page 78: ...11 Maintenance 74 R5906852 F80 SERIES 21 09 2017...