5. Installation
Image 5-7
Light output, CLO mode
Image 5-8
5.2.4
Light sensor calibration
What can be done ?
Depending on the used screen type,
fl
at, scope,
fl
at3D or scope3D, a different
fi
le has to be loaded for the
light sensor before starting the calibration. By loading a different
fi
le the light output can be made equal
for both screen types.
How to select a calibration
fi
le
1. Switch on a white test pattern via the pattern short cuts.
2. Tip on
Activate light sensor calibration
fi
le
to select the light sensor calibration
fi
le (1). (image 5-9)
A
fi
le selection window opens (2).
3. Select a
fi
le out of the list (3) and tip
OK
(4).
The selected
fi
le is loaded and will be used to calibrate the light output
126
R59770488 COMMUNICATOR TOUCH PANEL 06/06/2012
Summary of Contents for DP2K Series
Page 1: ...Communicator Touch Panel User guide For DP2K DP4K series R59770488 05 06 06 2012 ...
Page 10: ...Table of contents Index 277 6 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 36: ...2 Controls 32 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 170: ...5 Installation Image 5 44 Image 5 45 166 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 180: ...5 Installation Image 5 54 Cloning TI board 176 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 201: ...5 Installation Image 5 76 Image orientation R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 197 ...
Page 202: ...5 Installation 198 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 214: ...6 Maintenance Image 6 12 IP selection 210 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 239: ...7 Touch panel Image 7 17 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 235 ...
Page 245: ...7 Touch panel Image 7 23 Edit color palette R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 241 ...
Page 274: ...8 Macro editor 270 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...
Page 280: ...A Source settings 276 R59770488 COMMUNICATOR TOUCH PANEL 06 06 2012 ...