Troubleshooting
44
If you installed your B
ARCO
C
ORONIS
F
USION
Display System drivers
in
SingleView
mode (default for Windows 2000) there will be
one rectangle for the virtual display representing the two heads
controlled by each Coronis display controller.
If you installed your B
ARCO
C
ORONIS
F
USION
Display System drivers
in
DualView
mode (default for Windows XP) there will be a
rectangle representing each head controlled by each Coronis
display controller. This will be true even if you have only one
display connected to your Coronis controller. Both displays of a
display controller cannot be enabled at the same time unless
their display properties match. If necessary detach the second
display of the Coronis display controller you are working with by
right clicking on the
rectangle
that represents it, deselect
Attached
and click the
Apply
button.
Note:
Since Windows will not let you detach the primary
display connected to a particular controller, you may need to
temporarily make another display the primary display
4.
For the display which is still attached click Click on the
Advanced
Button.
5.
Select the
Adapter
tab and then click on the
List All Modes
button. Select the resolution and refresh rate that your B
ARCO
C
ORONIS
F
USION
Display display supports from the dialog box and
click
OK
.
Note:
In the Adapter box, the Adapter string shows if this
display is the First View or the Second View attached to the
display controller. Please make a note of this, so that you can
arrange the displays in the correct order later if necessary.
6.
Click
OK
on the bottom of the
Adapter Control Panel
. If the
“OK”
button on the bottom of the
Adapter Control Panel
is not visible,
press the
TAB
key once and then press
CTRL+Enter
to select
OK
.
7.
Click
OK
in the “Windows will now apply your new desktop
settings” dialog box. Your B
ARCO
C
ORONIS
F
USION
Display display
should now synchronize and display the Windows desktop.