Page 1: ...ENABLING BRIGHT OUTCOMES MDCG 3221 User Guide Coronis 3MP LED Display...

Page 2: ...Registered office Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com Barco NV Beneluxpark 21 8500 Kortrijk Belgium www barco com en support www barco com...

Page 3: ...tor lights 18 3 3 Standby switching 19 3 4 Bringing up the OSD menus 19 3 5 Navigating through the OSD menus 20 3 6 I Luminate 20 4 Advanced operation 21 4 1 OSD menu language 22 4 2 OSD menu automati...

Page 4: ...ale conversion modes 32 4 23 EDID timings 33 4 24 Display info 33 4 25 Display status 33 5 Repackaging instructions 35 5 1 Replacing the protection buffer 37 5 2 Repacking your display 37 6 Cleaning y...

Page 5: ...5 K5902060 09 Coronis 3MP LED Display Welcome 1...

Page 6: ...klights Barco s Coronis 3MP LED Display is as low in power consumption as it is high in brightness Additionally Barco s LED backlights are mercury free produce less heat and last longer This allows Ba...

Page 7: ...0 09 Coronis 3MP LED Display 7 1 3 Product overview Front 2 1 3 4 5 6 7 8 Image 1 1 1 USB A 2 0 downstream connector 2 Left key 3 Right key 4 Menu key 5 Standby key 6 Power status LED 7 Front sensor W...

Page 8: ...video input 4 DVI video input 5 Ethernet connector1 6 USB B 2 0 upstream connector 7 USB A 2 0 downstream connector 8 Connector compartment cover 9 Kensington security lock 10 VESA mount cover plate...

Page 9: ...are using a Barco display controller please consult the user guide delivered with it to do this For a list of compatible display controllers please refer to the latest version of the compatibility ma...

Page 10: ...ilt the panel upwards before changing the orientation Image 2 2 3 To change from portrait to landscape turn the panel counterclockwise 4 To change from landscape to portrait turn clockwise If after in...

Page 11: ...ltaneously will result in driver errors To connect the signal cables to the display To get access to the connectors remove the connector compartment cover See Removing the connector compartment cover...

Page 12: ...external DC power supply to the 24 Vdc power input of the display 5 Plug the mains connector of the external DC power supply to a grounded power outlet by means of one of the supplied power cables Im...

Page 13: ...se this to move the display Please refer to the instruction manual of the arm for more information and instructions WARNING Use an arm that is approved by VESA according to the VESA 100 mm standard Us...

Page 14: ...clean and soft surface Be careful not to damage the panel screen 3 Remove the plastic cover with a flathead screw driver Image 2 11 4 Slide the plastic cover over the neck of the foot Image 2 12 5 Rem...

Page 15: ...you have properly installed your display and display controller the Windows start up messages will appear once the boot procedure is finished Your Coronis 3MP LED Display will be running in a basic vi...

Page 16: ...K5902060 09 Coronis 3MP LED Display 16 Display installation...

Page 17: ...17 K5902060 09 Coronis 3MP LED Display Daily operation 3...

Page 18: ...ased on pixels As a normal tolerance in the manufacturing of the LCD a limited number of these pixels may remain either dark or permanently lit without affecting the diagnostic performance of the prod...

Page 19: ...or approximately 2 seconds As a result the display will switch on or will switch to standby mode In case of a power outage recovery your display will always start up in the power mode it was in before...

Page 20: ...above the keys adapted to the function that it is used for menu dependent I Luminate is not available while the OSD menu is activated Overview key icons Left Right Menu Enter Cancel Standby IEC 60417...

Page 21: ...21 K5902060 09 Coronis 3MP LED Display Advanced operation 4...

Page 22: ...ace Menu menu 3 Enter the Automatic Close submenu 4 Select Enabled Disabled as desired and confirm 4 3 Power status indicator light About the power status indicator light By default when the display i...

Page 23: ...Ethernet over USB About Ethernet over USB By default the Ethernet over USB will be disabled This does not disable the USB hub and still allows to make use of the display s USB downstream connectors an...

Page 24: ...s desired and confirm 4 8 DPMS mode About DPMS mode Enabling the Display Power Management System DPMS mode on your display will optimize its diagnostic lifetime by automatically switching off the back...

Page 25: ...The I Luminate default mode defines the default activated mode during the I Luminate boost This mode is Screen The boost mode is applied on the screen display To enable disable I Luminate 1 Bring up...

Page 26: ...others To respond to these conclusions display functions have been defined These functions emphasize on these parts containing crucial diagnostic information by correcting the native panel behavior Th...

Page 27: ...composed a list of pre defined reading rooms Each of these reading rooms are defined by following parameters the maximum light allowed in this type of room the preset ambient light correction value fo...

Page 28: ...display using the OSD menus described in the next sections Embedded QA will use the front sensor I Guard to measure the necessary luminance levels for either a calibration or compliance test Various...

Page 29: ...ion is shown Time elapsed since latest calibration Display Function Ambient Light Compensation and Reading Room Current DICOM Settings Display Function Shows the current display function Ambient Light...

Page 30: ...he DICOM compliance can be modified in steps of 5 starting from 5 to 30 When the maximum deviation is not bigger than the selected threshold the compliance check will be OK To set the DICOM error thre...

Page 31: ...t corresponding to the DVI connector Automatic Selection The input is automatically selected To manually select a video input signal 1 Bring up the OSD main menu 2 Navigate to the Configuration Image...

Page 32: ...ayscale conversion modes About grayscale conversion modes Grayscale conversion modes specify how color generated on the display controller is converted to grayscale in your display The available grays...

Page 33: ...elect Refresh Rate Preferred Orientation or Color Depth 5 Select one of the available settings and confirm 4 24 Display info About display info Your display serial number native resolution firmware ve...

Page 34: ...K5902060 09 Coronis 3MP LED Display 34 Advanced operation...

Page 35: ...35 WARNING Before repacking the display follow the instruction to replace the foot protection buffer to prevent damage to the display K5902060 09 Coronis 3MP LED Display Repackaging instructions 5...

Page 36: ...isplay 36 Overview of the packaging 1 2 3 4 5 6 7 8 Image 5 1 Packaging 1 Bottom box 5 Box Power supply cables 2 Bottom buffer 6 Top buffer 3 Protection buffer 7 Top box 4 Display 8 Display controller...

Page 37: ...put the panel in landscape orientation see Adjusting the display position page 10 5 Place the connector compartment cover in the protection buffer 6 Slide the protection buffer over the foot of the di...

Page 38: ...60 09 Coronis 3MP LED Display 38 4 Put the top buffer on top of the display 5 Slide the top box over the bottom box 6 Use the three lock bayonets to lock the box 1 2 3 x 3 Image 5 3 Repackaging instru...

Page 39: ...39 K5902060 09 Coronis 3MP LED Display Cleaning your display 6...

Page 40: ...Alcohol solvents at higher concentration 5 Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia Detergents with abrasives Steel wool Sponge with abrasives Steel bl...

Page 41: ...41 K5902060 09 Coronis 3MP LED Display Important information 7...

Page 42: ...ly no applied part The equipment shall not be used with life support equipment The user should not touch the equipment nor its signal input ports SIP signal output ports SOP and the patient at the sam...

Page 43: ...using serious injury to a child or adult and serious damage to the device Malfunctions Disconnect the equipment s power cord from the AC inlet and refer servicing to qualified service technicians unde...

Page 44: ...land RoHS RoHS Barco RoHS MCV According to the Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products Also called RoHS of Chinese Mainland the...

Page 45: ...o the photo is based on the Standard of Electronic Information Products Environmental Friendly Use Period of Chinese Mainland 10 7 3 Regulatory compliance information Intended use The display is inten...

Page 46: ...es or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC responsible Barco Inc 3059 Premiere Parkway Suite 400 30...

Page 47: ...or an experienced technician for help Electromagnetic immunity The Coronis 3MP LED Display is intended for use in the electromagnetic environment specified below The customer or the user of the Coroni...

Page 48: ...0 4 3 3 V m 80 MHz to 2 7 GHz 3 V m Immunity to RF wireless communications equipment Test frequency MHz Band MHz Service Modulation Maximum power W Distance m Immunity test level V m 385 380 390 TETRA...

Page 49: ...e is approved according to the UL Demko regulations S E Indicates the device is approved according to the CCC regulations Indicates the device is approved according to the VCCI regulations Indicates t...

Page 50: ...e Caution Consult the operating instructions Indicates this device must not be thrown in the trash but must be recycled according to the European WEEE Waste Electrical and Electronic Equipment directi...

Page 51: ...though every attempt has been made to achieve technical accuracy in this document we assume no responsibility for errors that may be found Our goal is to provide you with the most accurate and usable...

Page 52: ...angle H V 178 Uniform Luminance Technology ULT Yes Per Pixel Uniformity PPU Yes Ambient Light Compensation ALC Yes Backlight Output Stabilization BLOS Yes I Guard Yes Maximum luminance 1700 cd m typi...

Page 53: ...ctive non reflective glass cover Recommended modalities All digital images except digital mammography Certifications FDA 510 K K131246 for General Radiology CE1639 MDD 93 42 EEC A1 2007 47 EC class II...

Page 54: ...THE COPYRIGHTHOLDER OR ANY OTHER CONTRIBUTOR BE LIABLE FOR DIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES HOWEVER CAUSED AND ON ANY TH...

Page 55: ...K5902060 09 Coronis 3MP LED Display 55 Important information...