Image 15-2: Sodium carbonate crystals.
This cleaning procedure assumes that the filters are already removed from their slots.
Take into account that the time needed to dry the dust filters may be 24 hours or more. For that, it's
recommended to have a second set of dust filters which can be used while cleaning the first set.
Required tools
•
Bucket with hot water
•
Sodium carbonate, 30 gram (handful) per liter hot water
How to wash and dry the dust filters?
1.
Make a solution with a ratio of 30 gram (a handful) sodium carbonate to 1 liter
hot water
.
2.
Soak the dust filters in the solution for
30 to 60 minutes
. The grease should be dissolved after 1 hour.
3.
If the dust filter is still clogged repeat this procedure from step 1.
4.
Rinse the dust filters with clean water to flush all grease residue away.
5.
Shake out all excess liquid by repeatedly swinging the filter to-and-fro in a centrifugal action.
6.
Then allow the filters to
dry thoroughly
.
Note:
Drying time of the dust filters can be up to 24h or more. Drying time can be shorter when being
done in a well-ventilated area.
Tip:
To speed-up drying, allow the filter(s) to dry at 50°C max in a well ventilated room.
CAUTION:
UNDER NO CIRCUMSTANCES SHOULD WET FILTERS BE INSTALLED BACK INTO
THE PROJECTOR. THIS CAN HAVE SERIOUS SAFETY CONSEQUENCES AS WELL AS
JEOPARDIZE THE INTERNAL OPTICS OF THE SYSTEM.
CAUTION:
Do not install/use damaged dust filters. Replace damaged dust filters immediately with
new dust filters of the same type. See
https://my.barco.com
for the correct replacement part.
15.4 Cleaning the lens
To minimize the possibility of damage to optical coatings, or scratches to lens surfaces follow the
cleaning procedure as described here precisely.
Summary of Contents for Athena
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Athena ...
Page 8: ...R5906790 04 Athena 8 ...
Page 28: ...R5906790 04 Athena 28 Installation process ...
Page 36: ...R5906790 04 Athena 36 Physical installation ...
Page 58: ...R5906790 04 Athena 58 Input Communication ...
Page 100: ...R5906790 04 Athena 100 Starting up ...
Page 126: ...R5906790 04 Athena 126 Lamp House ...
Page 130: ...R5906790 04 Athena 130 Preventative maintenance actions ...
Page 151: ...R5906790 04 Athena 151 1 Image 16 18 Removal and installation of the projector covers ...
Page 152: ...R5906790 04 Athena 152 Removal and installation of the projector covers ...
Page 160: ...R5906790 04 Athena 160 Specifications ...
Page 168: ...R5906790 04 Athena 168 Pin configurations ...
Page 169: ...169 R5906790 04 Athena Environmental information C ...
Page 178: ...Glossary R5906790 04 Athena 178 ...
Page 183: ...R5906790 04 Athena 183 ...