USE AND CARE INSTRUCTIONS
20
Never
lean over the grill cooking area while lighting
your gas grill. Keep your face and body a safe
distance (at least 18 inches) from the front of grill
when lighting your grill by match.
WARNING
!
!
If ignition does not occur in 5 seconds, turn the Control
Knob(s) and gas source OFF and conduct a leak test
as explained in the Use and Care section of this guide.
If no leaks are detected, wait 5 minutes for any gas
to clear and repeat the lighting procedure.
WARNING
!
!
WARNING
!
!
Should a FLASHBACK fire occur in or around the Burner
Tubes, follow the instructions below. Failure to comply
with these instructions could result in a fire or explosion
that could cause serious bodily injury, death, or property
damage.
Shut off gas supply to the gas grill.
Turn the Control Knobs to OFF position.
Open the Grill Lid.
Put out any flame with a Class B fire
extinguisher.
Once the grill has cooled down, clean the
Burner Tubes and Burners according to the
cleaning instructions in this Use and Care
Guide.
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Troubleshooting
If the grill fails to light :
Misalignment of Burner Tubes over Orifices
Correction:
Reposition Burner Tubes over Orifices.
Obstruction in gas line
Correction:
Remove fuel line from grill. Do not smoke! Open
gas supply for one second to clear any obstruction from fuel
line. Close off gas supply at source and reconnect fuel line
to grill.
Plugged Orifice
Correction:
Remove Burners from grill by removing the
screws from the rear of each Burner using a Phillips Head
Screwdriver. Carefully lift each Burner up and away from
gas valve Orifice. Remove the Orifices from gas valve and
gently clear any obstruction with a fine wire. Then reinstall
all Orifices, Burners, screws and cooking components.
If an obstruction is suspected in Gas Valves or Manifold,
call the Grill Information Center 1- 800-474-5587
Monday - Friday 8:00am-4:30pm PST.
Obstruction in Burner Tubes
Correction:
Follow the Burner Tube cleaning procedure on
page 22
of this Operator's Manual.
Misalignment of Ignitor on Burner
Correction:
Check for proper position of the Electrode Tip
as shown in
steps 8 on page 13.
The gap between the
Spark Electrode Tip and Spark Receiver should be
approximately 3/16" wide. Adjust if necessary. With the
gas supply closed and all control knobs set to OFF. Press
the Electric Ignitor cap and watch for the presence of
sparks at the end of each electrode.
Disconnected Electric Wires
Correction:
Inspect the Ignitor Junction Box found behind the
Control Panel. Connect loose Electric wires to Junction Box
and try to light the grill.
Weak AA battery
Correction:
Remove the Ignitor Cap and replace the bat-
tery.
If the grill still does not light you may need to purge
air from the gas line or reset the regulator excess gas
flow device.
Note:
This procedure should be done every
time a new LP Gas tank is connected to your grill.
Turn gas off at source and turn Control Knobs to OFF. Wait
at least 5 minutes for gas to clear, then retry.
If your grill still fails to light, check gas supply and
connections.
Repeat lighting procedure. If your grill still fails to oper-
ate, turn the gas off at source, turn the Control Knobs to
OFF, then check the following:
1.
2.
3.
To purge air from your gas line and/or reset
the regulator excess gas flow device:
Turn Control Knobs to the OFF position.
Turn off the gas at the tank valve. For Natural
Gas close Shut Off Valve.
Disconnect regulator from LP Gas tank.
For Natural Gas disconnect regulator from
12 ft. Natural Gas Hose.
Let unit stand 5 minutes to allow air to purge.
Reconnect regulator to the LP Gas tank.
For Natural Gas reconnect regulator to
12 ft. Natural Gas Hose.
Turn tank valve on SLOWLY 1/4 of a turn.
For Natural Gas open Shut Off valve.
Open the Grill Lid.
Push and turn the Right Main Burner Control Knob
to IGN/HIGH.
Press the Electric Ignitor for 3-4 seconds to light
the burners.