19
UNILUX-3 40 / 52 / 55 / 65
Directions for use and Installation Instructions
° Now connect the fl exible hoses to the 2 collar adaptors (Ø125 mm) on
the top of the fi re and to the metal fi tting box on the air exit grids that
are being used (do not forget to fi t hose clamps).
° Ensure that the fl exible hose connections are gastight.
° The air exit grids cannot be fi tted until a few days later, once the
masonry has been pointed and allowed to dry. If one or more channels
are connected leading to other rooms, these rooms must be fi tted with
closable grids. These are available from your dealer, as well as the
fl exible hoses and clamps required.
° Within a range of 30 cm either side and 50 cm above the escape
opening (exit grids), there must be no fl ammable materials (e.g.
wooden ceiling, fi tted furniture).
• Clad the appliance on the top, sides and rear up to the front edge with an
approx. 10 cm thick ceramic insulation wool fi reblanket. Leave a few
centimetres clearance between the front of the chimney breast and the
appliance.
• Level off the appliance.
• Make a good seal between the smoke outlet from the appliance to the
chimney. See also 3.3.4.
Ensure that the entire fl ue is gas-tight.
• Ventilate the chimney, by placing ventilation openings at the top and
bottom of the chimney breast.
Summary of Contents for Unilux-3 40
Page 2: ...2 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 4: ...4 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 6: ...6 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 54: ...54 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 55: ......
Page 56: ...04 010713 326587 ...