21
UNILUX-3 40 / 52 / 55 / 65
Directions for use and Installation Instructions
Available BARBAS grids (option) for ventilating the fi replace:
COLOUR
DIMENSION (cm)
CLEAR OPENING (cm
2
)
Brass or white
13.5 x 13.5
75
(incl. fi tting)
Brass or white
27.0 x 13.5
150
(incl. fi tting)
Perma Air (white)
43.0 x 22.0
550
• If the fi re is to be placed against a bearing wall or against a wall containing
fl ammable material, an air gap of at least 20 mm should fi rst be created.
Before it a false wall, 100 mm thick, must be built of masonry or aerated
concrete.
• If the fi re is not placed against a bearing wall or a wall containing fl ammable
material, no false wall is necessary. Layers of insulation of at least 100-mm
thickness will then be suffi cient (class A1, DIN 4102-compliant).
See also section 3.3.
• After four weeks, your fi re will be ready for use.
3.3.4 Connecting the smoke outlet
The appliance comes with a detachable smoke outlet top-connection;
Ø150 mm (Ø148 mm external). This connection is intended for steel stovepipes,
double/single-skinned stainless steel (insulated) fl ues or double/single-skinned
fl exible stainless steel fl ues.
After the appliance has been installed, it can be connected to the fl ue.
In order to be able to disassemble the smoke outlet connection, remove the fl ue
gas fl ap and the brake plate fi rst.
See section 11 for the disassembly sequence: “Sequence for replacing the
interior of the appliance”.
Use of the smoke outlet REAR-connection possibility is not permitted!
Summary of Contents for Unilux-3 40
Page 2: ...2 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 4: ...4 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 6: ...6 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 54: ...54 UNILUX 3 40 52 55 65 Directions for use and Installation Instructions ...
Page 55: ......
Page 56: ...04 010713 326587 ...