5.2.6
Make the electrical connection
Caution:
• Use a wall socket with earth connection.
• The socket must be accessible at all times.
1.
Connect the plug to the wall socket.
2.
Make sure that the electrical cable does not touch the appliance, due to the high
temperatures of the appliance.
5.2.7
Connect the concentric flue system
1.
Connect the concentric flue system to the appliance. Use the materials that are
specified in the preparation manual. Do not use any other materials.
2.
Make sure that all mechanical connections of the concentric flue system are correctly
connected.
3.
Attach the concentric connection pipes to the wall or ceiling with metal brackets.
Refer to the manual 'assembly instructions for concentric flue system'.
5.2.8
Connect the convection set (optional)
1.
Put the collar adaptors in the open convection air outlet openings.
Figure 27. Position of convection air outlet openings
2.
Bend out the 3 lips on each collar adaptor, to attach the collar adaptor on the outlet
opening.
Installation
42
Gas Fire Front 70-60
Summary of Contents for Gas Fire Front 70-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...