1
Non-flammable hearth
2
Convection air inlet
3
Steel studs
4
TV wall mount bracket
5
TV
6
Convection air outlet
7
Concentric flue
8
Non-flammable material
4
9
Air gap and spacers
10
Non-flammable insulation plate
11
Cable duct
Figure 21. TV installation - flush mounted
A
Minimum 30 cm
B
Minimum 2.5 cm horizontal clearance between front of TV and front of the fireplace
enclosure
C
Minimum 5 cm clearance at all 4 sides of the TV
D
Minimum 2.5 cm
E
Minimum thickness 4 cm
F
Minimum 3 mm clearance between appliance and surrounding construction
4
Specifications according the installation instructions of the manufacturer of the concentric flue system
and local regulations.