4
Clearances
Warning:
• Obey the instructions in this section. Failure to follow these instruction can
create a fire hazard.
• Do not put the appliance directly against a flammable or non-flammable
wall.
4.1
Insulating material requirements
• Use insulating plates with a maximum thermal conductivity of 0.10 W/m.K or a thermal
resistance of minimum 10 K.m/W. The table hereunder shows some examples of
suitable insulating plate materials.
• Do not use rockwool or glass wool. These materials cause a pungent and unpleasant
odor when the appliance is heated.
• Do not use mineral wool
Table 3: Examples of insulation plates
Examples of suitable plate material
Thermal conductivity
Promat Promatect L insulating board
0.083 W/m.K
Skamol Skamotec 225
0.06 W/m.K
Skamol Super-Isol
0.08 W/m.K
4.2
Clearances to flammable walls
Put a non-flammable insulation plate between the appliance and the rear wall and side
wall according figure 11.
Table 4 shows the minimum thickness of the insulation plates and the minimum
clearances to flammable materials and walls.
Attention:
Make sure there is a 3 mm clearance between the appliance and
the surrounding construction, to allow for expansion of the appliance during
use.
Clearances
22
Gas Fire Front 70-60
Summary of Contents for Gas Fire Front 70-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...