5.1.3
Requirements on the ventilation/convection air openings
• Install the following minimum openings in the fireplace enclosure to prevent
overheating of the appliance and fireplace enclosure.
Table 9: Overview of the minimum required ventilation/convection air openings.
Ventilation/
convection air
inlet opening
at the bottom of
the fireplace en-
closure
Ventilation/convection air outlet opening
at the top of the fireplace enclosure
Appliance with-
out convection
casing
Appliance with convection casing
Openings at the
top of the con-
vection casing
are open.
2 openings at
the top of the
convection cas-
ing connected
with flexible
convection
pipes Ø125mm
to 2 outlet open-
ings.
4 openings at
the top of the
convection cas-
ing connected
with flexible
convection
pipes Ø125mm
to 4 outlet open-
ing connec-
tions.
Partly via 2 flexi-
ble convection
pipes: Minimum
net 220 cm
2
Partly via 4 flexi-
ble convection
pipes: Minimum
net 440 cm
2
Partly via the in-
side of the fire-
place enclosure:
Minimum net 220
cm
2
Partly via the in-
side of the fire-
place enclosure:
Minimum net 220
cm
2
220 cm
2
(*)
440 cm
2
(**)
440 cm
2
(**)
Total 440 cm
2
(**)
Total 660 cm
2
(***)
The ventilation/convection air openings can be realized with the decorative 'BARBAS
AirBox’ insert air vents, by using:
• (*): 2x Barbas AirBox 160 or 1x Barbas AirBox 320
• (**): 2x Barbas AirBox 320
• (***): 2x Barbas AirBox 320 + 2x Barbas AirBox 160
Installation
Gas Fire Front 70-60
35
Summary of Contents for Gas Fire Front 70-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...