6
Installation requirements
6.1
Requirements on the installation of the appliance
• Make sure that the location agrees with the safety requirements. Refer to section
• Make sure the floor is made of concrete or a solid pedestal of non-combustible
material.
• For the BOX
30
75 without wood log storage module, make sure the floor is level. After
placement it is not possible to level the appliance.
• Make sure the floor can support the weight of the appliance. Refer to section
the weight of the appliance.
• Make sure that the floor temperatures below and in front of the appliance cannot be
higher than 85 °C, during use of the appliance. Refer to section
• The non-combustible floor must have a width that extends at least 150 mm from each
side of the appliance and a minimum depth in front of the appliance according the
.
• Make sure the room where the appliance is installed has correct ventilation.
• Make sure that combustion air can flow into the appliance without obstruction.
• If applicable, install a valve in the external combustion air pipe.
6.2
Installation on a natural stone platform
Obey the requirements if the appliance is put on a natural stone platform.
• The platform must have minimum
thickness of 3 cm.
• The platform must support the weight
of the appliance directly underneath it.
• Ask your natural stone dealer
for additional advice regarding the
specific type of stone in combination
with the appliance.
6.3
Requirements on the chimney
• Make sure that in case of use of an existing (masonry) chimney, it is in good order and
applicable for the appliance. Ask your dealer or chimney sweeper for advice.
• Make sure the flue system obeys the national and local applicable regulations.
• Make sure the weight of the chimney is not supported by the appliance.
• Only connect the appliance to a chimney that is also connected with other appliances
if it is permitted by local regulations and if the chimney allows to connect multiple
appliances to it. Ask your installer for advice.
• The flue system must have a temperature class designation of minimum T400.
• The inner diameter of the chimney must be minimum 180 mm over the total length.
• Use a steel chimney pipe with a wall thickness of minimum 2 mm between the
appliance and the existing chimney.
• Do not use more than 2 bends of 45°.