BOX
30
75
Label
Minimum distance to
flammable materials in
cm
Remark
Minimum distance to
non-flammable mate-
rials in cm
A
180
80
B
30
5
C
30
5
D
See remark.
Install a non-flammable hearth with
a thickness of minimum 5 cm (floor
stone) when the appliance is put on
a flammable floor.The width (E) of the
hearth must be minimum 15 cm from
each side of the appliance. The depth
of the hearth in front of the appliance
(D) is minimum 50 cm, when the hearth
is level with the floor. If the appliance
is put on a flammable platform, make
sure the depth of the non-flammable
hearth is the same size as the platform
in front of the appliance.
5
E
15
5
F
20
5
Note:
Heat radiation from the appliance can cause cracks in a floor plate of natural
stone if put directly in front of the appliance. Make sure the floor plate is
resistant to temperatures of more than 100 ºC. Refer to the supplier of the
natural stone for advice
Clearances
16
BOX 30 75