12
E6
Power supply voltage is
out range (voltage and/or
frequency)
Cooking zone
cannot be turned
ON
Power supply voltage is
out of range (see tech-
nical data for details)
Contact technical
support.
Wrong mains frequency
or mains voltage phase
signal problems
Contact technical
support.
Internal error in genera-
tor’s circuitry
Contact technical
support.
E7
Internal error
Cooking zones
are turned OFF
-
Contact technical
support.
E8
Fan failure
Corresponding
cooking zone is
turned OFF
Fan blocked by dust or
fabrics
Clean and remove
foreign bodies
Fan or module electro-
nics defective
Contact technical
support.
E9
Temperature sensor error
for cooking zone
Corresponding
cooking zone is
turned OFF
Temperature sensor
line for cooking zone is
open or short-circuited
Contact technical
support.
EA
Internal error
Cooking zones
are turned OFF
-
Contact technical
support.
Flash checksum error
Contact technical
support.
IGBT- Idle current too
high
Contact technical
support.
Heat sink sensor
broken or shorted
Contact technical
support.
EEPROM- data Error
Contact technical
support.
Coil selection error
Defect inductor or
wrong inductor
1. Re-plug
2. Contact technical
support.
MCU internal register
setting
Contact technical
support.
Gate power voltage out
of range
Contact technical
support.
ADC startup test failure
ADC bandgap voltage
invalid
Contact technical
support.
Capacitor Control
wrong signal Defect
hardware device
Contact technical
support.
EH
Temperature sensor stuck
for cooking zone
Corresponding
cooking zone is
turned OFF
Not enough temperatu-
re change after switch
on the hob
Cool down the glass
No temperature change
(min. 10 K / 5 min)
after cooking zone is
energized
Contact technical
support.
ER03
Continuous key activation
detected
Cooktop switches
off after 10 sec.
Water or cookware pla-
ced on TC’s SmartKiis
Remove water or
cookware from the
glass
ER20
Internal error inside TC
Cooktop switches
off
-
Contact technical
support.
EN
Summary of Contents for 1PZP9N
Page 1: ...1PZP9N 1PKZP9N...
Page 2: ......
Page 3: ...475 830 862 R 6 7 512 197 510 600 58 860 510 6 M15 M26 220x90 220x90 475 830...
Page 4: ...M35 M46 x4 A B...
Page 5: ...M55 M66 INDUCTION...
Page 6: ...M75 M86...
Page 7: ......
Page 9: ...1PZP9N 1PKZP9N...
Page 10: ...2 IT pagina 3 EN page 14...
Page 33: ...2 mm 1 2 MIN 50 mm 20 mm NO YES 3 4 Induction 5B 5A 6 25...
Page 34: ...26...
Page 35: ...27...
Page 37: ...1PZP9N 1PKZP9N...