background image

FORTÉ™ AP/BG MANUAL

August, 2022 (v4)

9

CALIBRATION

Though the Forté’s burrs and scale come calibrated to a high 
specification, they may need adjustments over time to meet user 
grinding expectations.

BURR CALIBRATION:

The Forté factory calibration will accommodate a wide range of brew 

methods. However, if the Forté is unable to grind finely enough or coarsely 
enough for a particular brew method at the finest and coarsest settings, 

respectively, follow the instructions below to recalibrate to factory settings, 

then adjust to fit the grind parameters.

1. 

Empty all beans from the grinder by setting the bean shut-off knob 

(3)

 to the ‘CLOSED’ position and grinding the remaining beans.

2. 

Remove the grounds bin 

(8)

 or PortaHolder 

(18, AP)

 from the scale 

platform 

(9)

3. 

Press the time mode 

(13)

 button, then the manual button

 (14)

 to 

put the grinder in timed manual mode.

4. 

Lower the micro adjustment 

(6) 

and macro adjustment

 (7)

 lever 

knobs all the way to the bottom of the range.

5. 

Insert the burr calibration tool 

(16)

 into the round calibration port, 

behind the discharge chute, until the tool settles into the head of 
the calibration screw inside.

6. 

Press the start button 

(11)

 to run the motor.

7. 

With the motor running, move the macro lever up to setting 2, step 

by step, or until burr contact is heard, whichever comes first. If no 

burr contact is heard, move the micro lever up to setting Q, or until burr contact is heard, whichever comes 

first.

8. 

If the grind setting is set to 2Q and the burrs are not in contact, use the calibration tool to turn the 

calibration screw toward the finer direction (as indicated on the tool) until a change in motor pitch is heard. 

This will move the burrs back to factory calibration.

9. 

If the burrs make contact prior to reaching setting 2Q:

a. 

Use the calibration tool to loosen the calibration screw slightly (in the opposite direction indicated on 
the tool), thus coarsening the calibration.

b. 

Move the macro lever up to setting 2, then the micro lever to Q. If burr contact is heard before reaching 
this setting, the calibration screw may need to be loosened further. 

B A R AT Z A

Summary of Contents for Forte AP

Page 1: ...ncorporates many features that accommodate both commercial and professional level home use including an all metal construction small footprint intuitive touch control panel an accurate built in scale...

Page 2: ...FORT AP BG MANUAL August 2022 v4 2 TABLE OF CONTENTS SAFETY INFORMATION 3 PARTS IDENTIFICATION 4 GRINDER SETUP 5 GRINDER OPERATION 6 CALIBRATION 9 CARE CLEANING 11 WARRANTY SERVICE 13...

Page 3: ...rd or plug If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Keep the appliance and its cord out of reac...

Page 4: ...r Burr Carrier 5 Burrs 6 Micro Adjustment Lever Knob 7 Macro Adjustment Lever Knob 8 Grounds Bin 9 Scale Platform 10 Grind Adjustment Buttons 11 Start Stop Buttons 12 Weight Mode 13 Time Mode 14 Manua...

Page 5: ...r will come installed in the Fort AP grinder To remove it pull firmly straight out of the grinder b The weight function is not usable with the PortaHolder installed as it covers the scale platform c I...

Page 6: ...l reduce the lifespan of the burrs CHOOSING A GRIND SETTING The settings shown in the table below should be used as a general starting point The actual grind size needed for a particular brew method w...

Page 7: ...n it the weight icon will begin to flash Press it to tare the scale To grind continuously with a real time weight readout on the display press the manual mode button 14 while in weight mode Then use t...

Page 8: ...n a substantial increase in weight in a few seconds during grinding This may indicate that either coffee is not being ground or that coffee is being ground more slowly than expected Ensure that the be...

Page 9: ...om of the range 5 Insert the burr calibration tool 16 into the round calibration port behind the discharge chute until the tool settles into the head of the calibration screw inside 6 Press the start...

Page 10: ...om the scale platform 9 Ensure that the scale platform is clear of any debris and that the screws on top are tightened so that the platform does not shift 2 Unplug the grinder Plug it back in and hold...

Page 11: ...inder 3 Grip the hopper and rotate it counterclockwise to unlock it 4 Lift the hopper up and off the grinder CLEANING THE HOPPER AND GROUNDS BIN 1 Empty the hopper and the grounds bin 8 of coffee 2 Wa...

Page 12: ...r burr carrier on top of the grind chamber It should sit level with the grind chamber and will not thread on properly if it is not level 2 Use the burr removal tool to rotate the upper burr carrier co...