2
I.
Technical Data:
Model:
Steaman II
Dimensions:
9.5” x 9.0” x 12”
Weight:
30lbs
Power:
15 Amps
110 Volts
50/60 Hz
1000 Watts
Water capacity:
2 Quart
Pressure:
70-75 PSI
Fuse:
12 Amps ¼ x 1¼ (Main)
3 Amps ¼ x 1¼ (Control)
II.
Operating Instructions:
1.
Carefully unpack and inspect the steam machine.
2.
Unwrap the power cord and assemble the side gun holster to either side.
3.
Remove the cap from the top of the unit and carefully fill the unit to the top using a funnel.
4.
For the first use only, use regular tap water. Only use distilled water after that.
5.
Close and tighten the cap.
6.
Plug in the unit into a 20 Amp, grounded outlet.
7.
Turn the unit “on.”
The power switch will illuminate immediately and the water level indicator will be illuminated as
well.
After approximately 20 minutes, the ready light will be illuminated and the machine is ready to be
put to use.
8.
Always use caution when working with a steam machine. Wear appropriate gloves and eye protection.
Hold small items with clamps, tweezers, or insulated materials.
When cleaning, hold the steam nozzle over a work tray approximately 2 inches from the item to be
cleaned. Press and hold the button to release as much steam as needed.
9.
When finished cleaning, release the red button and replace the steam gun into the cradle.
10.
Never work if the water level indicator is blinking or off! Immediately power down and refill the unit.
(See chapter IV)
III.
Helpful Hints
Always try to refill the unit in the mornings when the unit is cold.
Always use distilled water – this will greatly increase the life of the unit.
Never add water when the power switch is “on.”
Never remove the cap until ALL pressure is released
.
IV.
Refilling the unit
1.
Turn the main switch to the “off” position. The light on the power switch will be off.
2.
Turn the cap half of a turn and allow all of the steam inside the unit to escape from the side hole of the
cap. This will take a few minutes.
3.
Using heat retardant gloves carefully loosen and remove the cap from the top of the unit. Make sure all
the pressure is gone before removing the cap completely.
4.
Allow approximately 30 minutes for the machine to cool down.
5.
Add water into the unit as previously explained.
6.
Replace and tighten the steam cap.
7.
Turn the power switch to the “on” position.
8.
Allow the machine to warm up until the ready light is illuminated.