smoothly (turn the handwheel by hand), if it cannot be turned, please check the
machine;
2. Turn off the power, check whether the motor power connector is loose, plug it
in and restart it;
3. Check whether the upper needle stop position is correct, if not, please adjust
the upper positioning position;
4. If it still does not work normally, please replace the control box or spindle
motor and notify the after-sales service.
E10
Electromagnet overcurrent
1. Unplug the solenoid connector, if alarm E10, replace the control box and
notify the after-sales service.
2. If there is no alarm after removing the solenoid connector, please plug it back
in
1) Step on the front pedal to let the sewing machine perform thread clamping
and back-tacking. If alarms, please turn off start back-tacking and end
back-tacking, restart the control box, and then step forward. If alarms, please
turn off the thread clamping function and restart the electronic control, and step
forward again. If there is no alarm, replace the clamper.
2) Step on the front pedal to let the sewing machine perform thread clamping
and back-tacking. If it alarms, please turn off start back-tacking and end
back-tacking, restart the control box, and then step forward. If there is no alarm,
please turn off the thread clamping function and restart the control box, and
open start back-tacking function, step forward again, if it alarms, please replace
the back-tacking solenoid.
3) Step on the front pedal to let the sewing machine perform thread clamping
and back-tacking. If there is no alarm, please step back halfway to raise the
presser foot. If it alarms, please replace the presser foot solenoid.
4) Step on the front pedal to let the sewing machine perform thread clamping,
back-tacking and half anti-side trample. If there is no alarm, please back step
pedal to trim. If it alarms, please replace the thread trimming solenoid.
E09
E11
The positioning signal of main shaft
motor encoder is abnormal
1. Turn off the system power, check whether main shaft motor encoder
connector is loose or fall off, restore it to normal and restart the system.
2. Check whether the motor zero point correction setting is correct; Reset the
motor zero point correction; Whether there is oil on the encoder code plate,
please clean it if there is any;
3. If it still does not work normally, please replace the control box or main shaft
motor and notify the after-sales service.
E14
Main shaft motor encoder signal is
abnormal
1. Turn off the system power, check whether the main shaft motor encoder
connector is loose or fall off, restore it to normal and restart the system.
2. Check whether the grating is installed correctly (whether the grating screws
are tightened and whether the grating is in the center of the encoder).
3. Check whether there is oil on the encoder code plate, if there is, please clean
it up, and restart the system after recovery.
4. If it still does not work normally, please replace the control box or main shaft
motor and notify the after-sales service.
E15
Main shaft motor drive overcurrent
1. Please check whether the motor power cord has bad
contact;
2. Please check whether the motor power cord is crushed;
3. Please replace the control box or main shaft motor and notify the after-sales