No.
Items
Range
Default
Description
P80
Trimming engage angle
0-359
5
P81
Presser foot release buffer
working time (ms)
0-800
60
P83
Stopping strength after
trimming
10-100
20
P84
Trimming full output
time (ms)
10-990
60
P85
Periodic signal of trimming
output (*10%)
1-10
7
P86
Up and down needle position
distance
15-345
180
Up and down positioning distance angle (1 degree for every 4
values)
P87
Wiping thread return delay
time
10-990
50
Make sure the wiper returns to its original position
P88
Stopover distance
10-100
30
P89
AC overvoltage setting
500-1023
880
P90
Soft start first stitch speed
200-1500
400
P91
Soft start second stitch speed
200-1500
1000
P92
Correct the electrical angle of
motor
160
Reading the initial Angle of encoder, the factory default was set,
please do not change the values (parameter value cannot be
changed manually, random change it will result the control box and
motor abnormal or damaged).
P93
The starting time of the half
back pedaling function (ms)
10-900
100
P95
Periodic signal of the presser
foot first output action (%)
10-100
100
P99
Starting tight seam stitch
length
0-5.0
0.5
P100
Direction of starting tight
seam
0-1
0
P101
The start angle of thread
tension releasing
1-359
30
Thread tension releasing start angle (defined as 0°under
calculation)
P102
The stop angle of thread
tension releasing
1-359
180
Thread tension releasing end angle (defined as 0°under calculation,
must be greater than P101 parameter value)
P103
Thread tension releasing
strength
1-5
3
P105
Pattern freedom sewing mode
selection
0-9
0
0: OFF
1-9: Pattern freedom sewing mode
P107
Starting tight seam speed
100-1200
500
P108
Starting tight seam stitch
number
0-12
1
P109
The delay time before thread
wiping
5-990
5
Interval time before entering thread wiping action after finding the
upper positioning
P110
Trimming back time (ms)
60-990
65
Make sure the thread trimming device returns to its original