No.
Items
Range
Default
Description
P54
Thread trimming action time
(ms)
10-990
200
P55
Thread wiping action time
(ms)
10-990
10
P56
Power on and positioning
0-2
0
0: Always not to find the up needle position
1: Always to find the up needle position
P57
Presser foot solenoid
protection time (s)
1-60
5
Forced shutdown after hold time to prevent the electromagnet from
being hot for a long time
P58
Up needle position adjustment
0-359
90
Up position adjustment, the needle will advance stop when the
value decreased, the needle will delay stop when the value
increased.
P59
Down needle position
adjustment
0-359
270
Down position adjustment, the needle will advance stop when the
value decreased, the needle will delay stop when the value
increased.
P60
Testing speed (rpm )
100-3700
3500
Setting testing speed.
P61
Testing A
ON/OFF
OFF
Continuous running testing.
P62
Testing B
ON/OFF
OFF
Start and stop testing with all functions.
P63
Testing C
ON/OFF
OFF
Start and stop testing without all function.
P64
Test run time
1-250
30
P65
Test stop time
1-250
10
P66
Machine protection switch
selection
0-1
1
0: Disable
1: Testing zero signal
P69
Pattern freedom sewing speed
100-3000
2000
P70
Type
P71
Correction stitches distance of
manual button A
0-5.0
0
P72
Up needle position adjustment
0-359
Adjust up needle position, the displayed value will change with the
position of the handwheel, press "S" key to save the current
position (value) as up needle position.
P73
Down needle position
adjustment
0-359
Adjust down needle position, the displayed value will change with
the position of the handwheel, press "S" key to save the current
position (value) as down needle position.
P74
Tacking stitch length
compensation
-50~50
0
P75
Back-tacking stitch length
compensation
-50~50
0
P77
Opportunity point of
back-tacking for end
back-tacking in high speed in
free sewing mode
0-350
130
P78
The start angle of thread
clamping
5-359
100
P79
The stop angle of thread
clamping
5-359
270