Result Registers
Register 1
Register 2
Register 3
Register 4
Register 5
Register 6
SDI-12 Device/CMD 1 Result Lower
11102
11104
11106
11108
11110
11112
SDI-12 Device/CMD 2 Result Upper
11301
11303
11305
11307
11309
11311
SDI-12 Device/CMD 2 Result Lower
11302
11304
11306
11308
11310
11312
SDI-12 Device/CMD 3 Result Upper
11501
11503
11505
11507
11509
11511
SDI-12 Device/CMD 3 Result Lower
11502
11504
11506
11508
11510
11512
SDI-12 Device/CMD 4 Result Upper
11701
11703
11705
11707
11709
11711
SDI-12 Device/CMD 4 Result Lower
11702
11704
11706
11708
11710
11712
SDI-12 Device/CMD 5 Result Upper
11901
11903
11905
11907
11909
11911
SDI-12 Device/CMD 5 Result Lower
11902
11904
11906
11908
11910
11912
Result Registers
Register 7
Register 8
Register 9
Register 10
Register 11
Register 12
SDI-12 Device/CMD 1 Result Upper
11113
11115
11117
11119
11121
11123
SDI-12 Device/CMD 1 Result Lower
11114
11116
11118
11120
11122
11124
SDI-12 Device/CMD 2 Result Upper
11313
11315
11317
11319
11321
11323
SDI-12 Device/CMD 2 Result Lower
11314
11316
11318
11320
11322
11324
SDI-12 Device/CMD 3 Result Upper
11513
11515
11517
11519
11521
11523
SDI-12 Device/CMD 3 Result Lower
11514
11516
11518
11520
11522
11524
SDI-12 Device/CMD 4 Result Upper
11713
11715
11717
11719
11721
11723
SDI-12 Device/CMD 4 Result Lower
11714
11716
11718
11720
11722
11724
SDI-12 Device/CMD 5 Result Upper
11913
11915
11917
11919
11921
11923
SDI-12 Device/CMD 5 Result Lower
11914
11916
11918
11920
11922
11924
SDI-12 Device Settings
The following are generic sampling, power and warmup parameters that should work for all SDI-12 devices. See the tested
device table below. In most cases, parameters will not need to be adjusted but if needed there are three common SDI-12
device parameters that control the communications and power of the SDI-12 device. Contact Banner Engineering Corp
support for more guidance.
•
Sample Rate. Formed using two 16-bit parameters, a HI word and a LOW word. The sample rate is how often the
SDI-12 device is powered up, then interrogated for data. The value in the registers is the number of 0.010 second
counts. For example, the default value is 22,500, which calculates to a sample rate of 22500 × 0.010 seconds.
Adjusting this value affects the battery life.
•
Warmup time. Amount of time to wait, in 0.010 second increments, from powering on the device to the time to
send communications to the device. The default value is 50, or 50 × 0.010 seconds. Adjusting this value affects the
battery life.
•
Voltage. The default voltage setting is 6 volts or a register value of 168. Adjusting this value affects the battery
life.
Registers (Default Value)
Device / Cmd Configuration
Enable
Device
Address
Switch
Power
Enable
Device
Command
Sample
Hi
Sample
Low
Warmup
Time
Voltage
SDI-12 Device/CMD 1
1751 (1)
11001 (48) 8
1754 (1)
11002 (10)
1752 (0)
1753
(22500)
1755 (50)
1756 (148)
SDI-12 Device/CMD 2
1701 (0)
11201 (49)
1704 (0)
11202 (10)
1702 (0)
1703
(22500)
1705 (50)
1706 (148)
SDI-12 Device/CMD 3
1651 (0)
11401 (50)
1654 (0)
11402 (10)
1652 (0)
1653
(22500)
1655 (50)
1656 (148)
SDI-12 Device/CMD 4
1601 (0)
11601 (51)
1604 (0)
11602 (10)
1602 (0)
1603
(22500)
1605 (50)
1606 (148)
SDI-12 Device/CMD 5
1551 (0)
11801 (52)
1554 (0)
11802 (10)
1552 (0)
1553
(22500)
1555 (50)
1556 (148)
8 The default device addresses 48 through 52 are in ASCII.
DXM100-Bx Wireless Controller Instruction Manual
50