1.3. EU Declaration of Conformity (DoC)
Banner Engineering Corp. herewith declares that these products are in conformity with the provisions of the listed directives and all essential
health and safety requirements have been met. For the complete DoC, please go to
Representative in EU: Spiros Lachandidis, Managing Director,
Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3, 1831 Diegem,
BELGIUM
Representative in UK: Tony Coghlan, Managing Director,
Turck Banner LTD
Blenheim House, Blenheim Court, Wickford, Essex SS11 8YT,
Great Britain
1.4. Overview
Use the SI-RF Radio Frequency Safety Switch to monitor the position of a guard to detect its movement, opening, or removal. A "guard" can be
a gate, door, cover, panel, barrier or other physical means that separates an individual from a hazard. Safety switches will issue a signal to the
machine control system to prevent or stop (halt) hazardous situations when the guard is not in the proper position. The SI-RF Safety Switch is
designed for non-locking guarding applications, unless another means of locking is provided.
The SI-RF Safety Switch is considered a Type 4 interlocking device per ISO 14119 that are actuated by an electronic field interacting with the
coded actuator typically mounted on the guard. Different levels of coded sensors are available: low, high, and unique.
Applications involving the use of the SI-RF Safety Switch should take into consideration the following standards:
•
ISO 13849-1/2 - Safety of Machinery - Safety Related Parts of Control Systems
•
ISO 12100 - Safety of Machinery - Risk Assessment and Risk Reduction
•
ISO 14119 - Safety of Machinery - Interlocking Devices Associated with Guards
•
ANSI B11.0 - Safety of Machinery - General Requirements and Risk Assessment
•
ANSI B11.19 - Performance Criteria for Safeguarding
The SI-RF Safety Switch can be used individually or in series. A series string can consist of 1 to 32 units. The redundant safety inputs are only
used for the serial connection of sensors (for an individual unit or last in the string they get tied to +24 V dc). The redundant safety outputs can
be used for serial connection of sensors or for the connection to the safety related parts of the control system.
Product
Directive
SI-RF Radio Frequency Safety Switch
EU: Machinery Directive 2006/42/EC
UKCA: Machinery (Safety) Regulations 2008