© Banner Engineering Corp. www.bannerengineering.com
1
P
RODUCT
O
VERVIEW
1. Product Overview
SI-RF Radio Frequency Safety Switch for interlocking and position monitoring
1.1. Models
In addition to the SI-RF sensor, a basic SI-RF system requires an actuator, a cable, and a safety monitoring device.
To order a 250 mm cable unit with a stainless steel connector, add a
CR
after the
P8
or
P5
. For example,
SI-RFDT-UP8
becomes
SI-RFDT-UP8CR
. Contact Banner Engineering for availability.
1.2. Important... Read this before proceeding!
The user is responsible for satisfying all local, state, and national laws,
rules, codes, and regulations relating to the use of this product and
its application. Banner Engineering Corp. has made every effort to provide complete application, installation, operation, and maintenance instruc
-
tions. Please contact a Banner Applications Engineer with any questions regarding this product.
The user is responsible
for making sure that all machine operators, maintenance personnel, electricians, and supervisors are thoroughly
familiar with and understand all instructions regarding the installation, maintenance, and use of this product, and with the machinery it controls.
The user and any personnel involved with the installation and use of this product must be thoroughly familiar with all applicable standards, some
of which are listed within the specifications. Banner Engineering Corp. makes no claim regarding a specific recommendation of any organization,
the accuracy or effectiveness of any information provided, or the appropriateness of the provided information for a specific application.
•
Sensor - Actuator pair with Unique, High, and Low code options
•
One SI-RF Safety Switch will meet Cat 4, PL e, or SIL CL 3 safety ratings
•
Series connection of up to 32 sensors, maintaining the highest levels of safety
•
Diagnostic options include In-Series Diagnostic (ISD) bussed signals and on-sensor LED codes
•
PNP auxiliary outputs on select models indicate the door status
•
Protection class rating of IP69
Model
Device
SI-RF Models
Coding
Diagnostics
Reset
Connector
SI-RFST-UP8
Sensor
Unique
Series PNP
Automatic
250 mm cable with an 8-pin M12
quick disconnect
SI-RFST-HP8
High
SI-RFST-LP8
Low
SI-RFSL-UP8
Unique
Manual
SI-RFSL-HP8
High
SI-RFSL-LP8
Low
SI-RFDT-UP8
Unique
In-Series
Diagnostic (ISD)
Automatic
SI-RFDT-HP8
High
SI-RFDT-LP8
Low
SI-RFDL-UP8
Unique
Manual
SI-RFDL-HP8
High
SI-RFDL-LP8
Low
SI-RFPT-U2M
Unique
Single PNP
Automatic
2 m cable
SI-RFPT-H2M
High
SI-RFPT-L2M
Low
SI-RFPT-UP5
Unique
250 mm cable with an 5-pin
M12 quick disconnect
SI-RFPT-HP5
High
SI-RFPT-LP5
Low
SI-RF-A
Actuator
Actuator/target for all switches
SI-RF-A2
Low Profile Actuator/target for all switches