Figure 11. Installation of Multiple Systems
Receiver
Emitter
Scan
Code 1
Scan
Code 2
Receiver
Emitter
Two systems in a horizontal plane
Receiver
Emitter
Scan
Code 1
Receiver
Emitter
Scan
Code 2
Two or three systems stacked (or alternate receiver/emitter
positions)
Receiver
Emitter
Scan
Code 1
Horizontal
Receiver
Horizontal
Emitter
Scan
Code 2
Two systems at right angles
Receiver 2
Emitter 2
Opaque Shield
Scan
Code 2
Scan
Code 1
Receiver 1
Emitter 1
Receiver 3
Emitter 3
Scan
Code 2
Multiple systems
WARNING:
•
Properly connect multiple pairs of sensors
•
Connecting multiple output signal switching devices (OSSD) safety outputs to one interface
module or otherwise parallel OSSD outputs can result in serious bodily injury or death, and is
prohibited.
•
Do not connect multiple pairs of sensors to a single device.
5.7 Mounting System Components
5.7.1 Mounting Hardware
After the mechanical layout considerations are addressed, mount the sensors and route the cables.
All brackets are ordered separately; no brackets are shipped with the sensors. The quantity of brackets ordered and the
placement of those brackets must ensure the unsupported distance (distance between brackets) is less than 900 mm (35.4
in).
S4B Safety Light Curtain
24
www.bannerengineering.com - Tel: + 1 888 373 6767