Operating Mode
Required
Event
Reset
Indicator
Status Indicator Zone Indicators
Diagnostic Displays
OSSD
Outputs
Alignment Mode -
All Beams Clear
Align all
beams
Double-flash Red
All on Green
Off
Off
Off
Run Mode - Clear
Perform
reset
On
On or Flashing
Green8
All On Green
Off
Off
On
Latched - Blocked
Beam 1 Blocked
Block
Beam 1
On
Red
Red or Green5
Off
Latched - Blocked
Beam 1 Clear
Block 1 or
More
Beams
On
Red
Red or Green5
Total number of blocked beams
Off
Latched - Clear
Clear all
beams
Flashing
Red
All On Green
Off
Off
Off
Noise Detected -
Reset Interface
Flashing
Continues
previous reading
Continues
previous
reading
Noise Detected -
EDM Interface
Continues
previous
reading
Continues
previous reading
Flashing
Lockout
Internal/
external
fault
Off
Flashing Red
All Off
on page
77)
Off
6.4.3 Status Indicators for Cascaded Applications
When multiple light screens are cascaded, some unique indications may occur.
When a receiver’s CSSI input is in a Stop condition (because of a blocked light screen further upstream in the cascade or
because of a Stop signal from an E-stop button, for example), the display on the downstream receivers, including the
master receiver, will be bracketed by a pair of vertical “goalposts.”
Receiver #1 (Master)
Condition
OSSDs
Display
Reset Indicator
Status Indicator
Clear
On
On
Green
CSSI Stop (Receiver #2, 3, or 4 is blocked)
Off
On
Red
Latch
Off
Flashing
Red
Receiver #2, 3, or 4
Condition
OSSDs
Display
Reset Indicator
Status Indicator
Clear
On
On
Green
Blocked
Off
# of beams blocked
On
Red
CSSI Stop (Receiver upstream is blocked)
Off
On
Red
8 Flashing if Reduced Resolution is enabled.
EZ-SCREEN
®
14/30 mm Safety Light Screen
54