D12 Expert Series – 

TEACH-Mode Fiber Optic Sensors

One-button programmable sensors for use with glass or plastic fibers

Printed in USA

P/N 41974G8B

**NOTE:9 m (30') cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., D12EN6FP W/30)

D12 Expert Series Glass Fiber Optic Models

D12 Expert Series Plastic Fiber Optic Models

Models

Switching Threshold

Setting

Cable**

Supply

Voltage

Output Type

Maximum Range

D12EN6FV

Just above the “dark”
condition

2 m (6.5')

10-30V dc

NPN (sinking)

Range varies by sensing mode and fiber
optics used; see page 11.

D12EP6FV

PNP (sourcing)

D12E2N6FV

Midway between “dark”
and “light” conditions

NPN (sinking)

D12E2P6FV

PNP (sourcing)

D12EN6FP

Models

Switching Threshold

Setting

Cable**

Supply

Voltage

Output Type

Maximum Range

Just above the “dark”
condition

2 m (6.5')

10-30V dc

NPN (sinking)

Range varies by sensing mode and fiber
optics used; see page 12.

D12EP6FP

PNP (sourcing)

D12E2N6FP

Midway between “dark”
and “light” conditions

NPN (sinking)

D12E2P6FP

PNP (sourcing)

IMPORTANT: SEE SAFETY USE WARNING ON PAGE 4

D12 Expert Features

Fiber optic sensors for DIN rail mounting; 10 to 30V dc operation

Visible red (680 nm) light source; models for use with either glass or plastic fibers 

High optical sensing power when needed, also excels at low-contrast sensing

Easy TEACH-mode programming automatically adjusts sensitivity to optimal setting*

D12E sensors are designed for low-contrast sensing applications (switching
threshold set to just above the “dark” condition)

D12E2 sensors set their switching threshold midway between the “dark” and
“light” conditions to ignore subtle changes, such as web flutter

Output may be programmed for either light or dark operate 

Fast 200 microsecond sensing response; Programmable 40 millisecond pulse
stretcher

Secure one-button programming is easy to use; one button sets both TEACH and
sensor configuration settings 

7-segment LED bargraph indicates relative received signal strength and sensing
contrast, programming status, and diagnostic trouble warnings

Marginal sensing alarm

Separate input allows remote programming by an external device, such as a
switch or a process controller

*U.S. Patent #5808296

Summary of Contents for Expert D12 Series

Page 1: ...E2P6FP PNP sourcing IMPORTANT SEE SAFETY USE WARNING ON PAGE 4 D12 Expert Features Fiber optic sensors for DIN rail mounting 10 to 30V dc operation Visible red 680 nm light source models for use with...

Page 2: ...ming Modes TEACH Mode All photoelectric sensing applications excluding analog response applications involve differentiating between two received light levels The condition with the higher received lig...

Page 3: ...dels were first developed to ignore a small amount of web flutter in high speed registration color mark sensing applications At the end of the TEACH mode process the D12 Expert bargraph indicator flas...

Page 4: ...ontrast level and alarm Construction Black ABS Cycolac KJB housing with acrylic cover stainless steel M3 x 0 5 hardware for use with VALOX mounting bracket supplied the plastic fiber clamping element...

Page 5: ...Slide the fiber gripper up open For 010 or 020 dia fibers insert the small fiber adaptor into the ports as far as it will go B Insert the prepared plastic fiber sensor ends gently into the ports as fa...

Page 6: ...maximum sensitivity Use the following TEACH mode procedure at any time to return the sensitivity to its maximum setting Following the TEACH mode procedure on page 8 teach the following two conditions...

Page 7: ...nger Output settings are displayed Two steady red LEDs indicate the output settings light or dark operate and output timing 0 or 40ms NOTE The sensor continues to operate normally during the display p...

Page 8: ...l automatically return to RUN mode if the push button is not clicked within 10 seconds Double click ON indicator green LED single flashes at 1 Hz Green ON LED single flashes at 1Hz and the 7 segment d...

Page 9: ...ansistor The timing diagrams Figure 5 below define single double and triple click simulating the D12 Expert s programming push button The ON time of each click must be at least 40 milliseconds The min...

Page 10: ...n RUN mode with the most recent settings Display LEDs 1 and 7 flash together 6 times Figure 8 Problem This occurs at the end of TEACH mode when the sensor has received faulty data Faulty data may resu...

Page 11: ...For a complete selection of fibers in these sizes and for more information see your current Banner Photoelectric Sensors Catalog Qty Required for Each Unit 2 2 2 1 0 7 mm 027 individual pair IMM 443S...

Page 12: ...ge OPPOSED MODE 0 5 mm 02 bifurcated PBT26U 0 5 mm 02 individual pair PIT26U 84 mm 3 3 1 0 mm 04 individual pair PIT46U 315 mm 12 4 1 5 mm 06 individual pair PIT66U 660 mm 26 0 25 mm 1 0 1 0 mm 04 bif...