Dynamic TEACH
SET Button
0.04 seconds < "Click" < 0.8 seconds
Remote Input
0.04 seconds < T < 0.8 seconds
Result
Note: TEACH Selection must be programmed to dYn tcH (see
on page 3 )
Enter Ad-
just Mode
• Set Mode switch to ADJ
No action required; sensor is
ready for Dynamic TEACH
method
Display: Red - Signal Level;
Green - Threshold
Enter Dy-
namic
TEACH
• Click the SET rocker but-
ton
• Single-pulse remote input
T
Display: Flashes "dYn tch"
then holds on "1234 dYn"
Present ON
and OFF
Conditions
• Present ON and OFF con-
ditions
• Present ON and OFF con-
ditions
Display: Red - Signal Level;
Green - Threshold
Exit Dy-
namic
TEACH
• Click the SET rocker but-
ton
• Single-pulse remote input
T
TEACH Accepted
Displays alternate "PASS"
with % Minimum Difference*,
Sensor returns to Adjust mode
TEACH Unacceptable
Displays alternate "FAIL" with
% Minimum Difference*, Sen-
sor returns to Adjust mode
Return to
RUN Mode
• Move Mode switch to RUN No action required; sensor re-
turns to RUN mode automati-
cally
Display: Red - Signal Level;
Green - Threshold
* See
on page 19 for more explanation of the % Minimum Difference displayed after the Dynamic TEACH method