background image

D10 

Expert

 Dual Discrete Outputs

2   

 

P/N 64154 rev. F

 

Banner Engineering Corp. 

• 

Minneapolis, MN U.S.A.

www.bannerengineering.com  •  Tel: 763.544.3164

Figure 1.  D10 features

dynamic

static

Output 

Indicators

Output Select 

Indicators

4-Digit 

Display

Light/Dark 

Operate, Clock 

and Lock Icons

Programming 

Push Buttons

For emitter and receiver port 

locations, see page xx.

Overview

The D10 

Expert

 Sensor is a high-performance plastic fiber-optic sensor whose many 

configuration (TEACH-mode) options make it suitable for demanding applications. Even with 
all its features, it is extremely easy to use. Advanced 16-bit microcontroller technology makes 
this possible.

The D10 

Expert

 

provides high-performance sensing in low-contrast applications. 

Expert 

TEACH and setup options provide static, dynamic and single-point programming plus manual 
fine adjustment, remote programming and push button lockout. Its slender, stylized housing 
has a large digital display visible beneath a clear cover for easy programming and status 
monitoring during operation. The sensor mounts directly to standard 35 mm DIN rail or using 
the supplied mounting bracket. 

The sensor features two outputs with independent setpoints: either NPN or PNP, depending 
on model. Built-in crosstalk avoidance protocol provides trouble-free operation for multiple 
sensors in one area.

Light/Dark 
Operate Selection

Toggle to select the condition for which each output will conduct: when the target is present or when the target is absent.

OFF-Delay Timing 
Selection

Programmable OFF-delay pulse stretcher: 0, 2, 5, 10, 15, 20, 30, 40, 60, 80, or 100 milliseconds

Display Selection

Discrete Output: Raw signal value or % excess signal

Power Level/
Speed Selection

Super High-Speed† (SHS)

High-Speed (HS)

High-Power (HP)

Super High-Power (SHP)

Response*

50 µs

200 µs

1 ms

2.5 ms

Repeatability

25 µs

50 µs

75 µs

100 µs

Maximum 

Range*

Fiber

Red 680 nm

Green 525 nm

Red 680 nm

Green 525 nm

Red 680 nm

Green 525 nm

Red 680 nm

Green 525 nm

PIT16U

20 mm

9 mm

30 mm

9 mm

55 mm

13 mm

90 mm

16 mm

PIT26U

100 mm

40 mm

150 mm

40 mm

250 mm

55 mm

400 mm

70 mm

PIT46U

300 mm

100 mm

550 mm

100 mm

1000 mm

160 mm

1200 mm

180 mm

PIT66U

600 mm

180 mm

1000 mm

180 mm

1700 mm

280 mm

2400 mm

320 mm

PBT16U

6 mm

**

10 mm

**

18 mm

3 mm

30 mm

3.5 mm

PBT26U

30 mm

12 mm

50 mm

12 mm

100 mm

20 mm

150 mm

25 mm

PBT46U

100 mm

30 mm

175 mm

30 mm

250 mm

42 mm

300 mm

60 mm

PBT66U

175 mm

55 mm

250 mm

55 mm

400 mm

80 mm

475 mm

100 mm

Tracking Feature

Sets Output 2 to identical settings as Output 1; Output 2 settings can then be revised as desired. (See Advanced Setup procedure, page 11.)

Factory Default 
Settings

The following settings are preset at the factory; revert sensor to factory defaults using Advanced Setup procedure (page 11). 

• Light operate (LO)   

• Output 1 displayed 

 

 

• Maximum power setting 

                   

 

• No OFF-delay (t 0)   

• High Speed (HS); 200 µs response 

• Discrete: switchpoint positioned at middle of range

 

• Raw signal value (1234) 

  * Diffuse mode performance based on 90% reflectance white test card. 
** ø0.010" bifurcated fiber not recommended in these speed settings. Contact Banner Applications for more information. 
  † See note on page 10.

Summary of Contents for D10 Expert

Page 1: ... m or 9 m 6 5 or 30 cable or integral Pico style quick disconnect Sleek ultra slim 10 mm housing mounts to a standard 35 mm DIN rail U S Patent 5 808 296 9 m 30 cables are available by adding suffix W 30 to the model number of any cabled sensor e g D10DNFP W 30 A model with a QD connector requires a mating cable see page 14 WARNING Not To Be Used for Personnel Protection Never use these products a...

Page 2: ... or when the target is absent OFF Delay Timing Selection Programmable OFF delay pulse stretcher 0 2 5 10 15 20 30 40 60 80 or 100 milliseconds Display Selection Discrete Output Raw signal value or excess signal Power Level Speed Selection Super High Speed SHS High Speed HS High Power HP Super High Power SHP Response 50 µs 200 µs 1 ms 2 5 ms Repeatability 25 µs 50 µs 75 µs 100 µs Maximum Range Fibe...

Page 3: ...ess and hold the Static button for 2 seconds to cancel out of SETUP mode press and hold both the Static and Dynamic buttons for 2 seconds Output 2 The setpoint s for each output can be set independently of one another see Super High Speed Operation However the functional range available for output 2 is dictated by the automatic power and gain settings established for output 1 Whenever output 1 is ...

Page 4: ...nual Adjust page 9 Static TEACH is the traditional setup method used when two conditions can be presented by the user The sensor locates a single sensing threshold the switchpoint midway between the two taught conditions with the Output ON condition on one side and the Output OFF condition on the other see Figure 2 The first condition taught is the ON condition The Output ON and OFF conditions can...

Page 5: ...ess and hold Dynamic button Hold remote line low to ground Display flashes dyn Arrow icon turns red TEACH Sensing Conditions Present Output ON OFF conditions while continuing to hold Dynamic button Present Output ON OFF conditions while continuing to hold remote line low to ground Return to RUN Mode Release Dynamic button Release remote line switch TEACH conditions acceptable Display flashes pass ...

Page 6: ... extends 200 counts above and below the taught condition including 100 counts hysteresis All other conditions lighter or darker result in OFF output Sensing window sensitivity is adjustable using and buttons see Manual Adjust page 9 Window SET is most useful when a product may not always appear in the same place or when other signals may appear Window SET designates a sensing window with the Outpu...

Page 7: ...st Sensor positions threshold slightly below the presented condition Sensor positions threshold slightly above the presented condition Darkest no signal Darkest no signal Most Light saturated signal Most Light saturated signal Darkest no signal Most Light saturated signal Condition Presented Output OFF Output OFF Output ON Output OFF Output ON Condition Presented Output OFF Output ON Condition Pre...

Page 8: ...ter 60 seconds sensor returns to RUN mode Arrow icon turns green without changing settings T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T Push Button Remote dynamic static dynamic static dynamic static dynamic static dynamic static dynamic static Mode Threshold Offset counts above taught signal value Super High Speed 30 High Speed 22...

Page 9: ...ing Threshold Fine tunes sensing sensitivity Press to increase press to decrease Sensing Window Adjusts sensing window size tolerance for the single point target condition Press to increase press to decrease Push Button Remote Result Manual Adjust Click to increase or click to decrease Not available with remote programming Display briefly flashes the threshold setpoint value as it is being changed...

Page 10: ...ouble pulse the remote line to toggle between selections OFF No OFF Delay t 0 Clock icon OFF 2 to 100 ms OFF Delay t 2 t 5 t 10 t 15 t 20 t 30 t 40 t 60 t 80 or t100 Clock icon ON Click Static to save selection and advance to Display Single pulse the remote line to save selection and advance to Display Select Display Parameters Click Dynamic to toggle between selections Double pulse the remote lin...

Page 11: ...mode quad click the remote line Indicator Arrow Icons 1 and 2 remain red Display shows Tracking Enabled option Track Enable Click Dynamic to toggle between selections Double pulse the remote line to toggle between selections Sets output 2 identical to output 1 Tracking disabled Display shows tr n Tracking enabled Display shows tr y Click Static to save selection and advance to Factory Default Sing...

Page 12: ...or 2 PNP depending on model Output Rating 150 mA maximum load OFF state leakage current 10 µA at 24V dc ON state saturation voltage NPN 1 5V at 150 mA load PNP 2 5V at 150 mA load Output Protection Circuitry Protected against false pulse on power up and continuous short circuit Output Response Time Programmable 50 microseconds 200 microseconds 1 millisecond 2 5 milliseconds NOTE 1 second delay on ...

Page 13: ...13 deep ø4 4 mm 0 18 thru 2x 3 5 mm 0 14 5 0 mm 0 20 8 6 mm 0 34 25 4 mm 1 00 16 0 mm 0 63 2 x ø3 3 mm 0 13 2x ø3 2 mm 0 13 2 5 mm 0 10 5 0 mm 0 20 M3 Hardware included Lock Washer 2 Flat Washer 2 Screws 2 Hex Nuts 2 Included Bracket Dimensions 61 3 mm 2 42 68 1 mm 2 68 Plastic Fiber Emitter Port Plastic Fiber Receiver Port 10 5 0 2 mm typ 0 41 Mounting Bracket included Slides Up to Release Fibers...

Page 14: ...Temperature 40 to 90 C 40 to 194 F Voltage Rating 30V ac 36V dc Style Model Length Dimensions Pin out 6 Pin Straight PKG6Z 2 2 m 6 5 PKG6Z 9 9 m 30 6 Pin Right angle PKW6Z 2 2 m 6 5 PKW6Z 9 9 m 30 28 mm max 1 1 ø 10 mm max 0 4 20 mm 0 8 25 mm max 1 0 ø12 mm max 0 5 Brown Wire Gray Wire Pink Wire Blue Wire Black Wire White Wire Hookups NPN Output Models PNP Output Models bu 12 24V dc 1 2 Teach Gate...

Page 15: ...P N 64154 rev F 15 D10 Expert Dual Discrete Outputs Banner Engineering Corp Minneapolis MN U S A www bannerengineering com Tel 763 544 3164 ...

Page 16: ...s its products to be free from defects for one year Banner Engineering Corp will repair or replace free of charge any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or ...

Reviews: