DXM HTTP Status
Contains cellular signal strength (if applicable) along with cloud push statistics. By default, the AMG is configured with
Push disabled (shown at the bottom of the screen). When cloud push is turned on (via the DXM Configuration Screen)
the status changes in this window to
Push Enabled.
DXM HTTP Status screen
Network Configuration
By default, the
Ethernet Mode
is configured with an IP address of 192.168.0.1 using the internal XML configuration file.
DXM Network Configuration screen
To manually change the IP address, toggle the
Ethernet Mode
to
Static
. Touch the Static IP Address fields and enter an
appropriate value. Press
Save
to apply the new settings. Toggle the
Ethernet Mode
field between
Static
,
DHCP
, and
XML
Config
(default settings and not intended to be user configured).
IMPORTANT:
Banner Engineering Corp. does not recommend manually changing the default IP set
tings of the internal XML configuration file. This can be detrimental to the programming of the AMG.
HMI Utilities Screen
HMI Details
Contains firmware and serial numbers of the internal HMI.