background image

Asset Monitoring Gateway with SNAP ID 
Instruction Manual

Original Instructions
p/n: 234288 Rev. A
July 17, 2023

© Banner Engineering Corp. All rights reserved.

Summary of Contents for AMG

Page 1: ...Asset Monitoring Gateway with SNAP ID Instruction Manual Original Instructions p n 234288 Rev A July 17 2023 Banner Engineering Corp All rights reserved...

Page 2: ...ecial Sensor Settings Screen 12 Initialize the VIBE IQ Machine Learning Algorithm 14 DXM Utilities Screens 16 HMI Utilities Screen 17 Chapter 4 Additional Information Push Information to BannerCDS 21...

Page 3: ...r SNAP SIGNAL and Modbus equipped sensors Connected units can be grouped and renamed All relevant in put registers can have threshold alarms assigned to them individually The alarm status is indicated...

Page 4: ...ith Ethernet connection M12 power and serial communications input connector PSW 24 1 power supply Polycarbonate enclosure STP M12 406 cordset not included with cellular models Mounting bracket packet...

Page 5: ...AMG HMI Home Screen Customize the gateway name located on the top title bar by tapping Enter title and typing in a custom name For help information click the help information icon in the top right cor...

Page 6: ...e to go to the main configuration device information menu Utilities screen 1 In the Sensor Utilities column touch Sensor Scan ID Assign The Sensor table will initially be unpopulated 2 Connect any sup...

Page 7: ...new sensor converter at a time The gateway scans for new devices based on the default SID 1 so it is also important to change all identified devices SID when you will be adding more than one device To...

Page 8: ...Blank page 8...

Page 9: ...cted or has a communications issue Thrhld1 or Thrhld2 indicates an active threshold alarm depending on the alarm that is triggered ID Displays the current device Modbus Server ID Group If the sensor i...

Page 10: ...the specific sensor Customize the sensor name by touching the text entry next to the name and entering a new name The details screen also provides a notes area intended for any applicable user data sp...

Page 11: ...pendant light on the top left corner of the enclosure Critical alarms red take priority followed by yellow then green for normal operation indication Set thresholds for specific registers by touching...

Page 12: ...e Sensor List Statistics screen Special Sensor Settings Screen The Special Sensor Settings screen contains the menus for specific sensor configurations including global Vibration algo rithm base setti...

Page 13: ...inable ACTIVE ON values are the x axis and z axis velocity acceleration The sample period is the cycle time the al gorithm uses to deem a sample applicable The algorithm discards readings under the de...

Page 14: ...d confirm The change is saved to the device locally and is stored to display in the sensor s statistics and data in all menus Sensor Custom Scaling IMPORTANT If you need to push sensor specific data t...

Page 15: ...er of samples the gateway has available preferably up to 300 and the average value of the parameters is shown 2 Press Undo if more samples are required The suggested banked samples needed to accuratel...

Page 16: ...CID fields only populate for cellular enabled devices DXM Configuration Contains options for pushing data to the Banner Cloud Data Services website The Cloud Push Enable toggle field de faults to No T...

Page 17: ...168 0 1 using the internal XML configuration file DXM Network Configuration screen To manually change the IP address toggle the Ethernet Mode to Static Touch the Static IP Address fields and enter an...

Page 18: ...tem Reset triggers an entire reset of the AMG Security Passwords Logout secures the device to the current configuration no settings can be changed without the administration password The default admin...

Page 19: ...et Monitoring Gateway With SNAP ID Instruction Manual 19 System Messages Contains communication messages critical error messages global settings and sensor scan data HMI System Messages screen Banner...

Page 20: ...Blank page 20...

Page 21: ...ormation on creating accounts on and using the Banner Cloud Data Services CDS system please refer to the Banner CDS Quick Start Guide p n 201126 or the Instruction Manual p n 178337 Create a New Gatew...

Page 22: ...s DXM Details screen 6 Click Save 7 On the HMI Go to DXM Utilities DXM Configuration to enable cloud pushing 1 Change the Threshold Filter to a number greater than 0 3 is recommended 2 Verify your dev...

Page 23: ...are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency ener...

Page 24: ...INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHER WISE Banner Engineering Corp reserves the right to change modify or improve the...

Page 25: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...