Banner AG4 Series Safety Laser Scanner
Place
Number Meaning
Activity
2804 3
The PF activation performed does not comply with
the specifications programmed in the
Scanner.
Check the activation of the PFs in the program wizard.
2804
4
No PF clearly selected.
Check the activation of the control inputs FP1 - FP4.
2804 6
Unusable or defective control voltage for the PF
activation.
Check the switchover times of the control inputs FP1 - FP4.
3016 11
Confirmed
single
password entered wrong.
Repeat the password entry.
3203 6
Scanner
has optical glare caused by another
device.
Switch off the supply voltage and start the Scanner again.
3203 7
Scanner
has optical glare caused by another
device.
Switch off the supply voltage and start the Scanner again.
3402 2
Motion Monitor, field pair activated wrong several
times. Speed exceeding can no longer be
corrected.
Check the activation of the PFs in the speed matrix and the speed the
vehicle moved at.
3402 3
Motion Monitor, speed very much exceeded.
Exceeding cannot be corrected.
Check the activation of the PFs in the speed matrix and the speed the
vehicle moved at.
3402 10
Motion Monitor, maximum speed exceeded or
wrong field pair activation. Cannot be corrected.
Check the activation of the PFs in the speed matrix and the speed the
vehicle moved at.
3403 7
Motion Monitor, activated field pair was not
released in the configuration.
Check the activation of the PFs in the speed matrix and the program
wizard.
3403 12
Motion Monitor, error on the field pair control
inputs. Activated PF not defined.
Check the activation of the
creep and further travel blocking
functions.
3406 8
Motion Monitor, further travel blocking cannot
switch off the safety outputs or switching function
(OSSDs).
Check the connection/wiring of the OSSDs.
Product Manual
P/N 144924 05/2009
75