Banner AG4 Series Safety Laser Scanner
a X1
socket
b X2
plug
The cable glands permit cable diameters of 6.5 to 10.5 mm.
Figure 33. Cable assembly
Assemble X1 cable
Table 5. X1 cable requirements
Plug
SUB-D, 15-pin
Socket
SUB-D, 15-pin
Wire gauge
Min. 0.5 mm
2
Cable external diameter
6.5 mm to 10 mm
Cable length
Max. 50 m
Assemble X2 cable
Table 6. X2 cable requirements
Plug
SUB-D, 9-pin
Socket
SUB-D, 9-pin
Wire gauge
Min. 0.2 mm
2
or 24 AWG
Cable external diameter
6.5 mm to 10 mm
Cable length
RS 232:
Max. 10 m
48
P/N 144924 05/2009