2.3
Pin assignment
2.3.1
Power supply
The PP15 requires an external 24 VDC power supply. The input current
at the nominal voltage is about 10 mA.
PP15 Power supply connector
+
_
1
2
3
Pin
Description
1
nom. + 24 VDC / max 30 VDC
2
Protective Earth
3
GND
Tab. 2: PP15 Power supply connector
2.3.2
Data ports
The PP15 is equipped with two data ports
–
CAN
–
RS232 (for service purposes and/or software upload)
PP15 Data port connectors
1
6
5
9
CAN
isolated
CiA DS 102-1
[CiA]
RS232
up to 115 kBaud
Pin
Description
Pin
Description
1
n.c.
1
n.c.
2
CAN_L
2
RXD
3
CAN_GND
3
TXD
4
n.c.
4
n.c.
5
n.c.
5
GND
6
reserved
6
n.c.
7
CAN_H
7
RTS
8
n.c.
8
CTS
9
n.c.
9
n.c.
Tab. 3: PP15 Data port connectors (CAN / RS232)
B&R PLC PP15 for use with the, d&b Remote network, Reference manual (1.1 EN)