background image

2.3 

Pin assignment

2.3.1 

Power supply

The PP15 requires an external 24 VDC power supply. The input current
at the nominal voltage is about 10 mA.

PP15 Power supply connector

+

_

1
2
3

Pin

Description

1

nom. + 24 VDC / max 30 VDC

2

Protective Earth

3

GND

Tab. 2: PP15 Power supply connector

2.3.2 

Data ports

The PP15 is equipped with two data ports

CAN

RS232 (for service purposes and/or software upload)

PP15 Data port connectors

1

6

5

9

CAN

isolated

CiA DS 102-1 

[CiA]

RS232

up to 115 kBaud

Pin

Description

Pin

Description

1

n.c.

1

n.c.

2

CAN_L

2

RXD

3

CAN_GND

3

TXD

4

n.c.

4

n.c.

5

n.c.

5

GND

6

reserved

6

n.c.

7

CAN_H

7

RTS

8

n.c.

8

CTS

9

n.c.

9

n.c.

Tab. 3: PP15 Data port connectors (CAN / RS232)

B&R PLC PP15 for use with the, d&b Remote network, Reference manual (1.1 EN) 

Page 9 of 16

Summary of Contents for PLC PP15

Page 1: ...B R PLC PP15 for use with the d b Remote network Reference manual 1 1 EN...

Page 2: ...Reference manual Version 1 1 EN 10 2010 DOC01009 Copyright 2010 by d b audiotechnik GmbH all rights reserved d b audiotechnik GmbH Eugen Adolff Strasse 134 D 71522 Backnang Telefon 49 7191 9669 0 Fax...

Page 3: ...2 3 User interface 8 2 3 Pin assignment 9 2 3 1 Power supply 9 2 3 2 Data ports 9 2 3 3 Digital inputs DI 10 2 3 4 Digital outputs DO 11 2 4 Uploading the d b software routines to the PP15 12 2 5 Conf...

Page 4: ...ge The monitoring function is particularly important when the system is used in accordance with IEC 60849 Sound Systems for Emergency Purposes Up to 255 d b amplifiers can be controlled and monitored...

Page 5: ...devices it is displayed on the error page of the PP15 with an error number and indicated as a general error message at the Error digital output In addition an error description in plain text can be re...

Page 6: ...p Sub Mismatch 8 Spkr Fault 9 Spkr Fault HF 10 Spkr Fault LF 11 Input Monitoring Fault 12 Amp Temp Warning Tab 1 D12 D6 and E PAC error numbers For further information on the error messages please ref...

Page 7: ...ys with LED display 5 Recalls the amplifier settings Preset assigned to a particular key via the d b Remote Network CAN Bus The following functions can be set using the d b configuration tool The LED...

Page 8: ...ge Extended functions Press F3 to access the page that provides several extended functions Scroll up down using the the Up Down keys 3 to place the requested function into the top line and press the E...

Page 9: ...2 3 2 Data ports The PP15 is equipped with two data ports CAN RS232 for service purposes and or software upload PP15 Data port connectors 1 6 5 9 CAN isolated CiA DS 102 1 CiA RS232 up to 115 kBaud Pi...

Page 10: ...Preset with the highest priority Note If no external wiring is required configure the Alarm contact digital input as high active N O contact normally open contact Terminal block connections X1 Digita...

Page 11: ...n an alarm signal is applied to input DI 16 An error message from a controlled amplifier is displayed at output DO 16 Error Simultaneously output DO 15 Buzzer emits periodic impulses 0 5 s high 4 5 s...

Page 12: ...or 2 4 3 2 1 and 6 5 8 7 9 Installation procedure 1 Adjust the 2 hex switches on the rear panel of the PP15 to values ranging from 01 to FE e g SW1 to 0 and SW0 to 1 2 Connect the PP15 to COM1 2 3 or...

Page 13: ...ted or not With the configuration tool the amplifiers to be controlled are registered in the PP15 dbCAN ID and the presets assigned to the respective keys or inputs are stored For a detailed descripti...

Page 14: ...The PP15 communicates with the amplifier via the CAN Bus and displays error messages from the amplifier at a central location point see 2 3 4 Digital outputs DO on page 11 Since amplifier boot time an...

Page 15: ...13 3 2 List of Tables Tab Table title Page Tab 1 D12 D6 and E PAC error numbers 6 Tab 2 PP15 Power supply connector 9 Tab 3 PP15 Data port connectors CAN RS232 9 Tab 4 X1 Digital Inputs DI 10 Tab 5 DO...

Page 16: ...DOC01009 10 2010 d b audiotechnik GmbH d b audiotechnik GmbH Eugen Adolff Str 134 D 71522 Backnang Germany Phone 49 7191 9669 0 Fax 49 7191 95 00 00_______...