2.4
Uploading the d&b software routines to the
PP15
Fig. 9: PVI Transfer software
To implement the functionality explained above in the PP15, the d&b
software routines have to be uploaded to the PP15.
Requirements:
–
Computer equipped with a serial COM port 1, 2, 3 or 4
(RS 232)
1
–
Serial cross cable (null modem cable)
Pin connector 1
1 and 6
2
3
4
5
7
8
9
Pin connector 2
4
3
2
1 and 6
5
8
7
9
Installation procedure:
1.
Adjust the 2 hex switches on the rear panel of the PP15 to
values ranging from 01 to FE (e.g. SW1 to 0 and SW0 to 1).
2.
Connect the PP15 to COM1, 2, 3 or 4 of the computer using
the serial cross cable and switch on the PP15.
3.
Extract the d&b software routines (.zip) and double-click the
"Start.bat" file.
The PVI Transfer software starts. The upload script is displayed.
1 This was also tested using an FTDI USB to serial adapter.
B&R PLC PP15 for use with the, d&b Remote network, Reference manual (1.1 EN)
Page 12 of 16