background image

- 15 -

Wireless charging system 210W specification

 

Single phase 100V, 

200V

To the power supply 

side

Power Supply  unit

Charging unit

(1)24V lead battery

(1) Parts of the dotted line (External device communication cable and 24V lead batteries) within the product 
is not included with this product. They are contents prepared and processed of a visitor.
(2) That the protection function is turned on, is 40.5 ℃ or more. (The installation situation, there is a differ-
ence about ± 2 ℃ .)
In addition, I have you use the attached article always, thermistor put it on the side of 24V lead 
batteries Please attach. In that case, please do not touch any terminal.
(3) Each cable, please connect with the specified length. You may receive an error due to the output such as 
a decrease occurs.

Connection diagram

Passive Head

Active Head

Power cable

Output cable

(2)Thermistor with Cable

(1)External 

device commu-

nication cable

(AWG28 ~ 16)

(1)External device 

communication cable

(AWG24 ~ 16)

Details of the charging unit input and output

24V lead battery

Load

Thermistor

フェライトクランプ

フェライトクランプ

フェライト

クランプ

電源ユニット

充電ユニット

給電ヘッド

受電ヘッド

Mounting of the ferrite clamp

The installation of the bundled ferrite clamp is necessary 
in addition to the upper figure to meet a standard of the 
EMC(IEC61000-4-3).
Please attach a ferrite clamp to a power cable by 2 turns 
with the following points each.

・It is one within 20cm from a power supply unit
・It is one within 20cm from a power supply unit to the 

power cable of the active head.

・It is one within 20cm from a passive head to the power 

cable of the passive head.

Charging 
unit

Power 
Supply  
unit

Passive Head Active Head

ferrite clamp

ferrite clamp

ferrite 
clamp

Summary of Contents for RCS Series

Page 1: ...h for purchasing the Wireless charging system RCS210 of B PLUS lately Before using this Processor read this manual carefully and operate properly paying attention to the safety aspects Wireless chargi...

Page 2: ...orbidden I indicates mandatory Please always run Caution Attention Caution I do not do the resolution and remodeling Failure to do so may result in fire electric shock or malfunction In addition there...

Page 3: ...h as a power in excess of the rated voltage there is a risk of overheating fire or malfunction To contact a specialized dealer or installation of equipment installation the wiring Improper by doing in...

Page 4: ...rself the standards and regulations to which the customer s system should conform The control communication device that is installed in the product there is no need for diploma radio station authoriza...

Page 5: ...the wiring 13 Connection diagram 15 6 Method of operation 16 How to switch on a power supply 16 How to turn off the power 16 About basic charge 16 Image behavior of the output voltage and current valu...

Page 6: ...power supply is changed into high frequency In response to the input signal start up signal and sup plies the high frequency to active head I will output to an external control device inzone signal v...

Page 7: ...unit and power supply unit according to the battery voltage If there is no inzone passive head when you connect the power of the default from external control de vices that are connected to the chargi...

Page 8: ...tion rating 19 6m sec2 10 55Hz Protection class IP20 Dimension 230 188 50 5 Weight 1 6kg Attachment hole dimensions 4 7x6 5 Connection Power supply connector Round 3 pin Communication connector Round...

Page 9: ...Operating humidity 90 RH No condensation Insulation 50M Ohm Dielectric strength 1500 VAC 1min Shock rating 10G each axis to x y z Vibration rating 19 6m sec2 10 55Hz Protection class IP20 Dimension 3...

Page 10: ...Charging unit at the male 3 pin round Power Connected to the Charging unit at the female 3 pin round Signal Connected to the Charging unit at the male D sub9 pin Signal Connected to the Charging unit...

Page 11: ...e width of the X axis Y axis is the following table For example X axis equals a 10mm Y axis 0mm If X axis is 5mm Y axis is less than 5mm If the product is used outside the range you may or equipment d...

Page 12: ...the head with an interval greater than or equal to the value shown in the table below always Head For R bending of the cable line Please make the following is greater than or equal to the number of R...

Page 13: ...oni tor signal Output Voltage monitor signal H 3 4 It is almost fully charged Charging aim about 90 Voltage monitor signal M 5 6 If the charge has been reduced somewhat Charging aim about 70 Voltage m...

Page 14: ...ing ON in charge cut off and float charging start Inzone signal I I will if ON is in the transmission area within the Active head Passive head Error signal N It turns on if a battery error occurs 7 Ab...

Page 15: ...eive an error due to the output such as a decrease occurs Connection diagram Passive Head Active Head Power cable Output cable 2 Thermistor with Cable 1 External device commu nication cable AWG28 16 1...

Page 16: ...wer supply unit turns off after about 10 seconds the operation stopped A and B when the power can be transmitted within the range When the power is turned off LED of power supply unit is All off after...

Page 17: ...ehavior of the output voltage and current value Operating to charging current 1 5A V V I A Output voltage Output current Output current 1 5A reach Float charging time CC charging time CV charging time...

Page 18: ...less charging system 210W specification 30Ah 5 hour rate Battery discharge about 50 Characteristics Reference CC CV charging characteristics Time minutes voltage current Charging current A Charging vo...

Page 19: ...alue I will move to this mode Charging voltage error Battery voltage outside of adaptation have been connected the voltage of the battery is down to abnormal Please connect the correct battery Battery...

Page 20: ...0mm or more away the head and to face again in about one minute The OFF contact OFF the start up signal After about 1 minute turns ON the start up signal Communication function Communication machine i...

Page 21: ...uired Up Inzone signal lights from entering the head transmission area 5s or less To start charging from the Inzone signal lights 5s or less Electric supply starting signal After ON if active head and...

Page 22: ...te in the state of ON in a voltage monitor demand the voltage monitor signal according to battery residual quantity is outputted in several seconds It is necessary to output voltage monitor request fr...

Page 23: ...23 Wireless charging system 210W specification...

Page 24: ...Mail b plus usa b plus kk com Web http www b plus kk com Contents is subject to change without notice Wireless Power Supply by...

Reviews: