C+
C-
F
F
For conditions to switch to the alarm mode and associated fog ejection,
see previous page. 6 "Alarm Input" and p. 12 "Flow chart".
If you do not want to use the confirmation input, put Dip C
OFF
and
leave both Conf. input terminals disconnected.
The
BANDIT
will then always switch directly into “alarm mode” without
the need for any confirmation.
Dip
C
ON
Dip
C
OFF
Confirm
Conf. LED lights as long
as there is 12 V present
on the Conf.-input
4
Input:
Confirmation input [Conf.]
Conf.
Conf.
C+
C+
C-
C-
G
G
A
A
C
C
F
F
Inputs
Inputs
ON
ON
2
2
1
1
3
3
4
4
Through this input permission to switch to “alarm mode” is provided to the
BANDIT.
The purpose of this feature is to postpone proceeding to “alarm mode” until
a local zone or intrusion detector confirms the burglary.
Features of the
confirmation input
[Conf.]:
The
BANDIT
can only switch to “alarm mode” if the Alarm input [Alarm] and
Confirmation input [Conf.] are simultaneously active while the device is
in Guard mode [Guard].
Control of the confirmation input [Conf.]
Depending on the position of dip-switch C, confirmation will be provided to
switch to the alarm mode from the alarm input [Alarm].
Logical truth chart for the Confirmation input [Conf.:
BANDIT
Controller CF31 v2
/ Manual v.102
Confirmation input - p. 7
12 V
on
Guard
No
voltage
on
Guard
No
voltage
on
Guard
12 V
on
Guard
on
yes
no
no
yes
off
off
on
F
15
Read
dips
Changes to dip-
switch settings
are only valid
once confirmed