Description:
Alarm panel connections:
- 12 V supply: possibly through fuse 1 AT.
- Monitoring output: the output relay is open as long as the alarm panel is
not
monitoring and closed as long as it is in monitoring mode.
- Alarm output: the output relay is open as long as the alarm panel is not
in an
alarm condition and switches to closed when in alarm.
- Tamper: Tamper is detected when the loop is interrupted.
- Dialler input 1: OKout output: Technical failures / problems are
reported
to the dialler when
NO
contact opens.
- Dialler input 2: Empty fog cartridge or "no power to
fog generator".
Both problems are reported together to the dialler when one or both
NO
contact ([Empty] or [Power]) opens.
PIR Confirmation sensor:
A typical PIR or better dual-technology (PIR / radar) sensor.
Objective: To delay the alarm status until a local zone detector confirms the
burglary signal of the alarm locally. The connected PIR / radar detector will
then open its contacts and the 12 VDC
on the confirmation input [Conf.] is
removed, and consequently the alarm mode is
confirmed.
Dip switch settings:
Dip G: is
ON
= the controller and the fog generator
are in monitoring mode [Guard] as long as there is
12
VDC
provided to the Guard input [Guard]
.
When
the controlling alarm system's
monitoring contact closes,
the orange Guard LED will light
and
BANDIT
is in monitoring status
.
Dip A: is
ON
= the controller and the fog generator
are in alarm mode
(Incl. fog ejection) as long as there is 12VDC provided to the alarm
input [Alarm].
So when the alarm system closes its alarm contact, the orange Alarm
LED will light and
BANDIT
is in the alarm status until removal of the
monitoring status.
Dip C:
is
OFF
=
when the connected sensor remains inactive, its alarm
contacts are closed, so there is 12
VDC
on the Confirmation
input [Conf.] and the orange LED Conf. is lit
When the sensor detects motion, it opens its alarm contacts
and so removes
the 12
over [Conf.], so confirmation to
VDC
switch to the alarm mode.
Conf.
C+
C-
Alarm
A+
A-
Guard
G+
G-
1 2 3 4
1 2 3
1 2
1 2 3 4
1 2 3
1 2
Front
Inputs
M³
G A C F
2 3
X
1
1 2 3 4
1 2 3
1 2
Guard
Guard
BANDIT
Controller CF31 v2
/ Manual v.102
Installation example 2 - p. 35