TL100
8
TL100
9
UK
UK
9
2
Connection of GIBIDI lights code AU02060 - AU02070 powered directly by the control unit.
9
3
Connection of external lights powered by the electric panel.
NOTE:
the value of the protection fuses must be
adequate for the power the external lights
require.
F
Type
Control unit
Electronic control unit for traffic lights
Power supply
Auxiliary output
Relay contacts
Operating temperature
Degree of protection
230VAC, single-phase, 50/60 Hz
24 Vac 250 mA max
250 Vac 16A
-20°C +60°C
IP55
TL100 / AS05180
The TL100 control unit can be used in situations where it is necessary to have orderly access control.
The control unit has two different types of operating logic:
1.
Time-based operating logic
The time the green and red lights (connected to the control unit) stay on are set by adjusting the dedicated
trimmers. No type of detection device is required.
2.
Operating logic with detection devices
The time the green and red lights (connected to the control unit) stay on are determined by the signals transmitted
by the detection devices, such as photocells, magnetic coils, etc.
• Green signalling LEDs for detection device input (D9 - IN1; D10 - IN2).
• Red signalling LED for limit switch input (D5).
• Detection device inputs independently settable to N.O. or N.C.
• Time adjustment trimmers.
• Dip switches for setting the operating mode.
• Possibilità di collegare lampade GBD a 24 V (cod. AU02060 and code AU02070).
• Possibility of connecting 230 VAC lights.
PRODUCT DESCRIPTION
TECHNICAL SPECIFICATIONS / FUNCTIONS
• Before proceeding with installation, fit a magnetothermal or differential switch with a maximum capacity of 10A
upstream of the system. The switch must guarantee omnipolar separation of the contacts with an opening distance
of at least 3 mm.
• To prevent possible interference, differentiate and always keep the power cables (minimum cross-section 1.5 mm²)
separate from the signal cables (minimum cross-section 0.5 mm²).
• Make the connections referring to the following tables and to the attached screen-print. Be extremely careful to
connect in series all the devices that are connected to the same N.C. (normally closed) input, and in parallel all the
devices that share the same N.O. (normally open) input. Incorrect installation or improper use of the product may
compromise system safety.
• Keep all the materials contained in the packaging away from children, since they pose a potential risk.
• The manufacturer declines all responsibility for improper functioning of the automated device if the original
components and accessories suitable for the specific application are not used.
INSTALLATION WARNINGS
AU02060
AU02070
AU02060
AU02070
1
2
FA
S
T
1
60
m
A
FA
S
T
5
00
m
A
F2
F1
TR1 TR2 TR3
D5
D9
D10
PH
AS
E
23
0
V
ac
N
EU
TR
AL
23
0
V
ac
M1
1
2
M2
3
4
24
Va
c
24
Va
c
- C
O
M
M3
F
C
A
5
6
7
8
9 10
F
C
A
IN
_1
IN
_1
IN
_2
IN
_2
J2
J3
M4
C
_1
11 12 13 14 15 16
R
_1
V
_1
C
_2
R
_2
V
_2
026G0
T1
SW1
ON
1 2 3 4 5 6
RED
ELECTRICAL BOX
1
2
FA
S
T
1
60
m
A
FA
S
T
5
00
m
A
F2
F1
TR1 TR2 TR3
D5
D9 D10
PH
AS
E
23
0
V
ac
N
EU
TR
AL
23
0
V
ac
M1
1
2
M2
3
4
24
Va
c
24
Va
c
- C
O
M
M3
F
C
A
5
6
7
8
9 10
F
C
A
IN
_1
IN
_1
IN
_2
IN
_2
J2
J3
M4
C
_1
11 12 13 14 15 16
R
_1
V
_1
C
_2
R
_2
V
_2
026G0
T1
SW1
ON
1 2 3 4 5 6
GREEN
230Vac / 24Vdc
RED
GREEN
230Vac / 24Vdc
F F
Summary of Contents for GI.BI.DI. TL100
Page 50: ...TL100 50 NOTE...