TL100
10
UK
TL100
11
UK
Terminal
M1
Position
Signal
1
N
2
L
Description
230 Vac power supply Neutral input
230 Vac power supply Line input
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
External light power supply output
External light power supply output
M2
3
24 Vac
4
24 Vac
See (2)
Opening limit switch input
Opening limit switch common
Detection device 1 input
Detection device 1 common. See Note.
Detection device 2 input.
Detection device 2 common. See Note.
M3
5
OPENING LIMIT
SWITCH
OPENING LIMIT
SWITCH
6
7
8
9
10
*IN_1
*IN_1
IN_2
IN_2
Lights 1 common
Red light 1
Green light 1
Lights 2 common
Red light 2
Green light 2
M4
11
*C_1
12
*R_1
13
14
15
16
*V_1
C_2
R_2
V_2
In the event of an operating fault or failure, cut the power upstream of the control unit and call Technical Service. Any
repairs must be carried out by specialised personnel using original and certified materials.
The product may not be used by children or persons with reduced physical, sensorial or mental capacities, or lacking
experience and knowledge, unless appropriately instructed.
Do not access the board for adjustments and/or maintenance.
WARNINGS FOR THE USER
• After installation, always carefully check proper functioning of the system and the devices used.
• This instruction manual addresses persons qualified for installation of "live equipment". Therefore, good technical
knowledge and professional practice in compliance with the regulations in force are required.
• Maintenance must be carried out by qualified personnel.
• Before carrying out any cleaning or maintenance operation, disconnect the control unit from the mains.
• This control unit may only be used for the purpose for which it was designed. Check the intended end use and take
all the necessary safety precautions.
• Use of the product for purposes different from the intended use has not been tested by the manufacturer, therefore
any work is carried out on full responsibility of the installer.
CAUTION: IMPORTANT SAFETY INSTRUCTIONS
It is important to follow these instructions in order to safeguard persons.
Keep this instruction booklet.
NOTE
If using detection devices already connected to gate opening control units, make sure that you connect the commons
to each other.
Position
Value
Type
500 mA
FAST
160 mA
F1
F2
FAST
Description
24 VAC output protection
Board protection
PROTECTION FUSES
Position
Description
Adjusts the time both red lights stay on to between 5 and 120 s.
Turn the trimmer clockwise to increase the time.
Adjusts the time the green light stays on to between 5 and 120 s.
Turn the trimmer clockwise to increase the time.
Adjusts the priority time to between 5 and 120 s. Turn the trimmer clockwise to increase the time.
TR1
TR2
TR3
TRIMMERS
CLOSED
CLOSED
J2
J3
Connects terminal 4 to terminal 11
Connects terminal 4 to terminal 14
JUMPER
NOTE
to be used if the lights are powered directly from the control unit. (2)
DIP
Function
Status
DIP 1
ON
OFF
DIP 2
ON
OFF
DIP 3
ON
OFF
DIP
4 - 5 - 6
ON
OFF
Selects the operating mode with detection devices
Selects the time-based operating mode
Configures the input IN_1 as N.C.
Not used
Configures the input IN_2 as N.O.
Configures the input IN_2 as N.C.
Configures the input IN_1 as N.O.
SETTINGS (DIP SWITCH - Sw1)
1.1. TIME-BASED OPERATING MODE (DIP 1 OFF)
At power on the control unit sets both red lights and tests the limit switch input. As long as the limit switch input
remains closed, the operating cycle is locked and the lights stay red.
When the limit switch input opens (gate open), the cycle as described below starts:
1. both lights stay red for the time T1, adjustable with the relative trimmer TR1;
2. when T1 has elapsed, the light connected to terminals “1” turns green for the time T2, adjustable with the relative
trimmer TR2, while the one connected to terminals “2” stays red.
3. when T2 has elapsed, both lights turn red again for the time T1 in order to free the passage;
OPERATION