BA24
30
UK
PROTECTION FUSES
Description
Value
Type
Accessories and motor protection, power supply from battery charger circuit.
10 A
/
Position
F1
Equipment, motor and safety devices protection.
10 A
/
F2
Accessories protection.
500 mA
FAST
F3
PROGRAMMING PROCEDURE AND SYSTEM CONFIGURATION
The system adjustments can be accessed via the display. There are 5 different menus marked with the
letters A, C, F, H and E.
1
To enter the programming procedure:
- start from the display as is shown in the picture
- Press simultaneously the keys ESC and OK for 3 seconds
(The writing Gbd will turn off)
ESC
OK
Gbd
-
+
2
The writing P A S S appears on the display.
Press the OK button to go to step 3.
Press the ESC button to exit and return to step 1.
ESC
OK
PASS
-
+
33
4 figures appear on the display ( 0 0 0 0 ), the first one is flashing.
With the + or – keys, the user selects the first digit of the installer
code.
When the required digit is selected, press the OK key to confirm
and go to step 4.
ESC
OK
0
0 0 0
-
+
33
The second figure is flashing.
With the + or – keys, the user selects the second digit of the
installer code.
When the required digit is selected, press the OK key to confirm
and go to step 5.
ESC
OK
4
0
0 0
-
+
4