background image

BA24

47

UK

H5

25

MOTOR 2 CLOSING TIME

H6

20

MOTOR 2 DECELERATION TIME

H7

5

LEAF 2 PHASE SHIFT TIME IN OPENING

H8

5

LEAF 1 PHASE SHIFT TIME IN CLOSING

H9

5

PAUSE TIME

H10

5

PEDESTRIAN OPENING TIME

H11

5

PEDESTRIAN PAUSE TIME

H12

0000

NUMBER OF CYCLES

H13

0000

INSTALLER CODE

H14

SOFTWARE VERSION  (format: R__xx)

xxxx

H15

NUMBER OF CYCLES DONE

0000

• Parameters type E:

E1

Y

PHOTOCELL 1 ENABLED

E2

Y

PHOTOCELL 2 ENABLED

E3

Y

SAFETY DEVICE (EDGE) ENABLED

Before powering the control unit , run the following tests:

FINAL CHECKS  AND TESTING

1-

2-
3-
4-
5-

6-
7-
8-
9-

10-

11-

12-

Check  the  electrical  connections:  improper  connection  may  be  harmful  to  both  the  control  unit    and  the 
operator.
Check proper position of the limit switches. 
Preset the mechanical stops in opening and closing.
Power the equipment. 
Check that the red LEDs of the normally closed contacts are on and the green LEDs of the normally open 
contacts are off. 
Check that the writing SAF does not appear on the LCD (intercepted or faulty edge).
Check that the relative LEDs turn off when limit switches work.
Check that the relative LED turns off when the photocells ray is intercepted.
Check that the relative LED turns off when the safety devices work.
Check that the motors are locked and ready to work with the “GATE COMPLETELY CLOSED”. 
Remove possible obstacles in the operating area of the gate, then give the command START. At the first 
command, the equipment starts opening, then check that the motion direction is correct.
If not  invert the wires in the terminals M1 and/or M2.
The  gate  will  stop  upon  reaching  the  first  opening  limit  switch.  It  is  necessary  a  complete  movement  to 
activate the regular working of the decelerations.

Gi.Bi.Di  advises  recycling  the  plastic  components  and  to  dispose  of  them  at  special 
authorised  centres  for  electronic  components  thus  protecting  the  environment  from 
polluting substances.

BA24 DISPOSAL

Summary of Contents for G:B:D: AS05100

Page 1: ...BA24 I UK F E D P NL BA24 AS05100 Apparecchiatura elettronica ISTRUZIONI PER L INSTALLAZIONE Electronic control unit INSTRUCTIONS FOR INSTALLATIONS GR...

Page 2: ...l se reserva el derecho de modificar los datos t cnicos sin previo aviso en funci ndelaevoluci ndelproducto POR FAVOR LEER CON ATENCI N ESTE MANUAL ANTES DE PROCEDER CON LA INSTALACI N Dieses Produkt...

Page 3: ...OPEN JP4 COM EL EL1 EL2 GND SPIA 24Vcc SEC JP5 JP2 RL1 RL2 RL3 RL5 RL4 RL6 RL7 RL8 RL9 F1 F3 BA24 D1 CF1 CF2 F2 LED STATUS ON OFF AC AC SK SK AS05020 CB24 230Vac 24Vac 24Vac PHOTO 1 COSTA PED NO FCA M...

Page 4: ...ter intervention of the safety devices At the next Start pulse the motion restarts in the obstacle freeing direction SEPARATE SAFETY DEVICES POWER SUPPLY Connect the safety devices that must be tested...

Page 5: ...ging away from children since they pose a potential risk The manufacturer declines all responsibility for improper functioning of the automated device if the original components and accessories suitab...

Page 6: ...l Service Periodically check functioning of the safety devices Any repairs must be carried out by specialised personnel using original and certified materials The appliance is not to be used by childr...

Page 7: ...ease the gate will start openingwithoutfurthercommands Ifinterceptedduringpause itreloadsthepausetime PHOTOCELL 1 input N C If not used disable during programming Operation Input active only during cl...

Page 8: ...inthepicture Press simultaneously the keys ESC and OK for 3 seconds ThewritingGbdwillturnoff ESC OK Gbd 2 The writing P A S S appears on the display Press the OK button to go to step 3 Press the ESC b...

Page 9: ...eytoconfirmand gotostep7 ESC OK 4 6 8 0 6 Now the installer code is complete go to step 8 If the installer code is not correct go back to step 2 ESC OK 4 6 8 3 7 The 5 main menus appear on the display...

Page 10: ...F H E 11 Use the and keys to select the submenus C1 C2 C3 C4 Press the OK button in sequence to enable the input the Y will appear next to C1 disable the input the N will appear next to C1 ESC OK C 1...

Page 11: ...digit Confirm with the OK button and go to step 17 ESC OK 0 1 0 0 16 The third digit blinks Use the or buttons to modify the value of this digit Confirm with the OK button and go to step 18 ESC OK 0...

Page 12: ...eyinsequenceto enabletheinput theYwillappearnexttoE2 disabletheinput theNwillappearnexttoE2 Usethe and keystoenterthefollowingorthepreviousmenu Use the ESC key to exit the menu ACFHE is now shown on t...

Page 13: ...setting the outputs for the electrical lock 2 can be used for a 3 minutes timed courtesy light 24V max 10W The activation of this menu automatically disables A5 1 MOTOR CONFIGURATION A4 Y MENU A SYST...

Page 14: ...t automatically closes the gate If the gate is open Start closes the gate Pedestrian is uninfluential during opening It will be active in pause if the pedestrian automatic closing is disabled In closi...

Page 15: ...following menu C1 C2 C3 KEY enters the previous menu C3 C2 C1 KEY ESC leaves the menu KEY OK activates Y yes disactivates N the function Enables total automatic closing H9 Enables pedestrian automatic...

Page 16: ...ith3longflashes 2sec PHASE 3 if the edge 8K2 is enabled when the Start or the Pedestrian command is given the COSTA Input is tested value 8K2 If the value isnotcorrect thefaultissignalledwith2longflas...

Page 17: ...tsthemotion NOTE ENABLE THE ANTI CRUSHING ONLY IF ALSO THE LIMIT SWITCHESAREENABLED Y2 ENABLED LIMITSWITCHAMPEROMETRIC The amperometric stops themotion N COURTESY LIGHT WITH TWO MOTORS C11 Y Activethe...

Page 18: ...or will automaticallycloseafterthepausetime Itisnotpossibletoactivatetheclosingwiththe start command WARNING remember to preset the automatic closing the activation of thismenuautomaticallydefuseC16 C...

Page 19: ...0010 maximum force F6 MOTOR 2 DECELERATION SPEED Adjusts the thrust of motor 2 during deceleration phase 0001 minimum force 0010 maximum force F7 MOTOR 2 FORCE AMPEROMETRIC Adjusts the amperometric t...

Page 20: ...er code it will be possible to delete the old one by pressing simultaneously the keys and for 3 seconds when the writingPASSappears In this way all the existing setting are erased and the default ones...

Page 21: ...the menu C21 menu C21 blinking By pressing OK the times programming procedure starts menu C21 Y fixed then 1 motor configuration START the leaf starts opening When the leaf arrives at the desired open...

Page 22: ...ues the decelerated motion for the time set in the menus H3 and H6 If using two limit switches the first one starts deceleration and the second one stops deceleration but does not lock the motion if T...

Page 23: ...ashings Photo 1 test failed at opening Blocked open door 4 fast flashings Photo 1 test failed at closing Blocked closed door 4 slow flashings Amperometric circuit test failed at opening Blocked open d...

Page 24: ...CRUSHING ENABLED C11 COURTESY LIGHT WITH 2 MOTORS DISABLED F2 Parameters type F F1 10 MOTOR 1 FORCE 05 MOTOR 1 DECELERATION F3 80 AMPEROMETRIC MOTOR 1 FORCE F4 50 AMPEROMETRIC MOTOR 1 DECELERATION Pa...

Page 25: ...ts are on and the green LEDs of the normally open contacts are off Check that the writing SAF does not appear on the LCD intercepted or faulty edge Check that the relative LEDs turn off when limit swi...

Page 26: ...enu C21 and select Y to activate automatic time programming then press START key see page 20 Time learning procedure Go to menu C5 to program slowdowns Go to menu C6 to choose the number of limit swit...

Page 27: ...s ELECTRONIC CONTROL UNIT BA24 are in conformity with the following CEE Directives EMC Directive 2004 108 CE and subsequent amendments and that the following harmonised standards have been applied Dat...

Page 28: ...DI S r l 46025 Poggio Rusco MN ITALY Tel 39 0386 52 20 11 Fax 39 0386 52 20 31 E mail comm gibidi com Numero Verde 800 290156 Via Abetone Brennero 177 B w w w g i b i d i c o m Cod AIC4976 12 2008 Re...